Laserfiche WebLink
TEST INSTRUCTIONS Socket <br /> POPPET & FLOAT MOVEMENT _ adaptor <br /> FOR TESTABLE MODELS ONLY =' <br /> TOOLS NEEDED FOR TESTING: <br /> 1 . 1 /4" square drive extension or 3/8" square drive ex- <br /> tension with 3/8" to 1 /4" socket adapter. <br /> 2. Torque wrench / 1 /411 or 3/8" square drive ratchet <br /> wrench . — <br /> 3 . Pipe dope. <br /> 4. Flashlight (optional). <br /> Open Poppet Closed Poppet <br /> TEST STEP 1 : Test Figure 1 <br /> Remove spill container cover and fill cap from fill adapt- <br /> er and look down into the tube and make sure no debris Pull on extension and <br /> or foreign objects are present. If debris or foreign ob- socket adaptor <br /> jects are present take appropriate steps before proceed- <br /> ing. Look down into the tube and ensure poppet is 'z?f � <br /> completely protected by the deflection shield . See Test ' x' , <br /> Figure 1 . If poppet is exposed and tank is not full the ` t <br /> overfill valve should be replaced. A flashlight may help _ <br /> when inspecting the tube. <br /> R, <br /> TEST STEP 2: J g j+i <br /> Unthread the socket adaptor assembly from the inlet <br /> tube using a 1 /4" square drive extension and wrench. i <br /> The extension will attach to the socket adaptor. Secure h <br /> all tools to ensure they don't fall into the tank or valve. <br /> With the extension still attached pull on the socket �- I <br /> adaptor and cable assembly and ensure float and pop- <br /> pet <br /> op pet move / function properly. It should only require 3" <br /> to 4" of movement and less than 5 lbs of force in order <br /> to actuate the float and poppet. When looking down <br /> into the upper tube ensure poppet is visible and moves <br /> into the flow path (see Test Figure 1 & 2) when socket Open <br /> adaptor is pulled and resets properly when socket adap- Poppet K Closed <br /> for is released. If poppet does not actuate freely take Poppet <br /> Float moves <br /> appropriate steps to correct. ' <br /> ,� up <br /> TEST STEP 3 : <br /> Apply pipe dope to the socket adaptor threads. Pipe <br /> dope should be a non-hardening gasoline resistant pipe <br /> thread seal compound . Make sure poppet and float f r <br /> have reset properly and are not visible then install sock- <br /> et adaptor and torque to 3 .5 ft-lbs (42 in-lbs) minimum <br /> to 5.0 ft-lbs (60 in-lbs) maximum. After installing socket <br /> adaptor, to ensure vapor tightness, OPW recommends <br /> conducting pressure testing per CARB TP201 . 1 D. Some Test Figure 2 <br /> areas may require pressure testing of overfill valve per <br /> CARB TP201 . 1 D to ensure valve is vapor tight. If the <br /> drop tube fails pressure testing it may be necessary to <br /> check the seal at the poppet adaptor threads. Reinstall <br /> fill cap and spill container cover after testing. <br /> 17 <br />