Laserfiche WebLink
NFIED,PROGRAM CONSOLIDATED FOO 1 J 03 <br /> TANKS ( / <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (Two pages per tank) <br /> Page I of 2_ <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ® 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430 <br /> (Check one item only) ❑ 3.RENEWAL PERMIT _update ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACT,rry NAME or DBA-Doing Business As) 3. 1 FACILITY ID: I <br /> ARCO Facility No.2186 <br /> LOCATION WITHIN SITE(optional) 431 <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK ❑Yes ® No 434. <br /> Unleaded-1 T US XERXES if"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 7/1999 20,000 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 438. <br /> H.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE 440. <br /> 19 I. MOTOR VEHICLE FUEL ®la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If checked,complete Petroleum Type) ❑lb. PREMIUM UNLEADED ❑3. DIESEL [16. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑1 c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materiels Inventory page) 441' CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE Gasoline <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> M.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑ 1. BARE STEEL 03. FIBERGLASS/PLASTIC ❑5. CONCRETE [195.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS [18. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC [18. FRP COMPTIBLE W/1000%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) [12. STAINLESS STEEL❑4. STEEL CLAD W/FIBERGLASS [19. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) [110. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED [13.EPDXY LINING ❑5.GLASS LINING [195.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED [199.OTHER <br /> Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC [13.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 44s. DATE INSTALLED 449, <br /> PROTECTION PROTECTION [14.IMPRESSED CURRENT ❑99.OTHER <br /> Applicable) [12.SACRIFICIAL ANODE <br /> SPELL AND OVERFILL YEAR INSTALLED 45o. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452 <br /> (Check all that apply) ®1.SPILL CONTAINMENT _1999_ _OPW_ ® 1.ALARM ®3.FELL TUBE SHUT OFF VALVE <br /> ®2.DROP TUBE 1999 OPW ❑2.BALL FLOAT ❑4.EXEMPT <br /> ❑3.STRIKER PLATE <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1.VISUAL(EXPOSED PORTION ONLY) [15.MANUAL TANK GAUGING(MIG) ❑I.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> [12.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> 1:13.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> [14.STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br />