HUNTER ENVIRONMENTAL SERVICES, INC. FINAL TEST RESULTS <br /> 18350.MT, LANOLEY STREET, SUITE 101 TEST DATE: 3/6/88 <br /> FOUNTAIN VALLEY, CA 92708 <br /> 800-247-9014 800-247-2186 <br /> CUSTOMER: ARCO LOCATION/IDENTIFICATION NO.: 2186 <br /> ADDRESS: 3212 N. CALIFORNIA <br /> STOCKTON, CA <br /> TEST RESULTS SUMMARY <br /> LEAK, LOKATOR RESULTS <br /> --------------------------------------------------------- <br /> SYSTEM TANK SIiE WATER LEVEL ALR <br /> ----------------- <br /> ND___PRODUCT--------GALLONS__DIA/MAIL---INCHES---------INCHES---------GPH-------CONCLUSION------RECOMMENDATIONS- <br /> 1 S/U 8000 95/ST 0 145 -.030 TIGHT <br /> 2 U/L 10000 92/FG 0 152 -.009 TIGHT <br /> 3 REG 10000 92/FG 0 149 -.008 TIGHT <br /> PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM ---TYPE-OF-PUMP--- <br /> POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br /> ---- -- ---- <br /> NO. PRODUCT REMOTE SUCTION APPLIED HELD HELD LOSS CC's LOTS GPH /RESULT <br /> ---------------------------------------------------------------------------------------------------------------- <br /> 1 S/U RED JACKET 50 50 15 PASS <br /> 2 U/L RED JACKET 50 48 15 PASS <br /> 3 REG RED JACKET 50 50 15 PASS <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> DETAIL OF TEST RESULTS <br /> - TEST ---- ------- --LEAK-RATE---LEAK:-RATE--- <br /> TEMPERATURE ABSOLUTE CHECK <br /> ---- ---- ---- <br /> SYSTEM TEST LEVEL CLOCK DURATION COMPENSATION LEAK RATE TEST <br /> NO. PRODUCT NO. (IN.) STATE (HR-MIN? CC/DIV CClMIN DELTA of CC/MIN CC/MIN GFH Y/N <br /> --------------------------------------------------------------------------------------------------------L---------- <br /> ! ` 9•'110 33 2.920 -2.920 -.003 -1.016 -1.90' -.0'30 "' <br /> ! SIU 1 4J 9:'110 ., <br /> 2 U/L 1 152 11:30 :33 2.098 -3.946 -.008 -3.366 -.580 -.009 N <br /> 3 REG 1 149 10:30 :30 2.864 -2.186 -.004 -1.673 -.513 -.008 N <br /> *LEVEL - Inches from Tank Bottom to Test Level <br /> ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br /> CONCLUSION - NFPA 323 criterion of +/- 0,05 GPA is used to certify tightness <br /> CERTIFICATION ��Rl <br /> This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br /> LOKATOR according to all standard operating procedures. Those indicated as tiqht at full system meet the criterion <br /> established by the National Fire Protection Association Pamphlet 321'9 for Precision Testing. <br /> Tests Conducted and Certified By: Test Van No. 19 <br /> Team Manager: R. RENKO <br /> Tank Testing Specialist: C. DORAZIO <br />