Laserfiche WebLink
(OPENINGS IN SLAB TO HAVE 1 - 1 /2" CROWN) <br /> 8, 5'-2" 12'-4' 5'-2" <br /> A <br /> 2,-0- <br /> IN OF <br /> TK3-5 (TYP. SNAN�kAR INSPECTION WELL <br /> MONITOR <br /> O aO <br /> M M <br /> Y Q <br /> Z Z VENT VAPOR RECOVERY - L- <br /> r }� <br /> ALL MANHOLE ACCESS COVERS 14 15 16 ((� <br /> Q p (STA E IQ TO BELOW GRADE SHALL BE /''� <br /> O Q �IQrnUIj TIGHT AND LOCKABLE 0 N C <br /> 4 E t SUN <br /> A.C. PAVING 6" CONCRETE TANK SLAB U ' <br /> O <br /> Q O " ] �2" 1-1/2" W/ 6X6/#4/4 WWM '^ <br /> n o * (T . ALL) t 2 TYP. TYFALL) TYP. TYP. 12 w <br /> w N +I A.C. PAVIN@ - r . it <br /> YZ \ .� TK3-5 -__ -�i..:y' • • _ - _ • • _ - - ,:} • z o .- T _i' _ :+-.-: =4y, • • 4 V,r C �.. h <br /> I` ~ FILL & VAPOR • '• • A, • •• ': • 'T ;}' • .4• <br /> Lu a)S Op J SLAB N RECOVERY (STAGE 1) _ 3" MIN. • r • • 1L U "�. C r/� <br /> 3ZV) N/ <br /> O Z TEMP ALIGNMENT SPACER //3 TOP & BOTTOM Q <br /> N Z O 2 ATTACHED IN FIELD IN 2 AROUND ALL PENETRATIONS (TYP) O Q ,- <br /> CONTROL FIELD TO MANHOLE SKIRT <br /> O Q EXPANSION (TYP. OF 41 TO BE REMOVED j <br /> C.7 C9 JOINTS TO BE AFTER INSTALLATION • N <br /> Z Z I "' "TOOLED" WITH /^ <br /> 3 O O T 3/8 RADIUS W <br /> � a0 M <br /> opo 0 <br /> N p O - NOTE: ,L <br /> Z O VENT/yAPOR RECOVERY ALL MANHOLES ON THE TANK SLAB SHALL BE INSTALLED WITH A 1-1/2" CROWN OF CONCRETE <br /> p O (STAGE II) TO PREVENT WATER INTRUSION INTO THE MANHOLE. THE ARCO FIELD ENGINEER WILL BE REQUIRED Cd <br /> Q <br /> U O TO SIGN OFF ON THIS ITEM ON THE TANK INSTALLATION CHECKLIST BEFORE CONTRACTOR WILL BE / <br /> PAID. CONTRACTOR WILL BE REQUIRED TO REINSTALL ENTIRE DRIVE SLAB AT OWN EXPENSE IF V <br /> ~O Ldl 6" x 6"-4/4 WWM THIS DESIGN REQUIREMENT IS NOT MET. <br /> Z V)Z:, (OR #3 ® 16" O.C) - <br /> Cd <br /> (TYP) CHAMFER E <br /> BOTTOMREBA2'CCO ERAGE OTYP. A T TO SCALETypical Slab at Tanks <br /> INSPECTION WELLJ A BETWEEN FILLS ALL AROUND PENETRATIONS - <br /> TK3-5 NO : C <br /> Typical Tank Slab Reinforcing <br /> i� <br /> NOT TO SCALE: ' <br /> t , <br /> FILTER FABRIC ON BOTTOM SEEER FABRICTE 1 +r <br /> OF TANK HOLE IN UNSTABLE (AS DEFINED BY SOILS REOUIRED DEADMAN DIMENSIONS - C <br /> REPORT) SOIL THE DIMENSION ' <br /> MUST BE 4 FT. FROM BOTH SIDES TANK DEADMAN DEADMAN DEADMAN NOTE: <br /> AND ENDS (WITH FIBERGLASS TANKS) TANK SIZE LENGTH LENGTH HEIGHT WIDTH <br /> ANGNHCINSER BLACK <br /> rAr B > > Ce D TAEACH FIRISER WH THE <br /> MIN PROPER PRODUCT I.D. TAG. DISTRIBUTION <br /> 10 FT, DIA. IS RESPONSIBLE FOR IDENTIFYING THE YANKS <br /> 20,000 GAL 37'-8 3/4' 38'-8 3/4" 12" 18 WITH A.P.I. COLORS. <br /> 2 -8" Cd > <br /> MIN �Q <br /> NOTES: o N .c a <br /> (1) FIL117ER FABRIC (DUPONT TYPAR OR MIRAFI 50OX) IS REQUIRED. Q• <br /> FABRIC MUST EXTEND 1 ABOE MAX. HIGH WATER TABLE O Q <br /> AND MAY BE PINNE4 TO SIDE OF HOLE WITH WIRE, ETC. SEAMSt 2 , <br /> 36 18" MUST BE LAPPED 1 MINIMUM. �♦ 1 CJ+ .� <br /> L <br /> Typical Anchoring for (2) TANK MUST BE BALLASTED BY FILLING WITH WATER UNTIL BACK FIL O -�� ,+,; •LL <br /> COMPLETE. CAUPON DO NOT FILL FIBERGLASS TANK WITH °Q(n •N Q C <br /> n LIQUID UNTIL BACK FILL IS EVEN WITH TOP. SEE SPECIFICATIONS <br /> (2) 10'-0 Diameter Tanks WHEN INSTALLATION IS COMPLETED, WATER IS TO BE COMPLETELY tU L 7 c C <br /> B _- PUMPED OUT & MOPPED DRY SO THAT NO PROBLEMS OCCUR w/ Q <br /> PHASE SEPARATION DURING WINTER OXYGENATED FUEL SENSOR. STANDARD DETAIL FOR 10" 12" C 0 C <br /> NOT TO SCALE: (3) DEADMEN TO BE <br /> ENGINEER LLEDOR AINTA WET HOLE HORITY HAVING R WHEN <br /> HE REQUIRED ♦ OTHER OR "MARKINGS SS CARE RPERMITTED, - 7^ b Cd Q BY ® 00 <br /> o <br /> WHEN REQUIRED, THE ANCHORING SYSTEM SHALL BE IN - �"' •@ U .0:F, T <br /> COMPLIANCE WITH AUTHORITY HAVING JURISDICTION. STAGE I VAPOR RECOVERY FILL PORT Cd r <br /> a NEW FIBERGLASS TANK U C (� 0 <br /> (4) WHEN GROUNDWATER LEVEL IS ANTICIPATED TO BE WITHIN 5 FT. 'G pp Eg Egpp R 0 •� o' <br /> Q FORGDIRECTIONRADE TONCANCHORING MET OD TOR SHALL NOTIFY TOOBEEUSEDLD N (DEADMAN FILL PORT PRGINEER ODUCT IDENTIFICATIO.N�R COLORED FOR Z Y ; r <br /> > CONCRETE "DEADMAN". WHEN MORE <br /> O THAN ONE TANK IS INSTALLED THE PER API STANDARDS. EPDXY MOUNTED CV V C <br /> d OR ANCHORING SLAB) <br /> DEADMAN BETWEEN TANKS SHALL BE INSTALLED BY ARCO DISTRIBUTION ca +-' 0 Q <br /> DOUBLE IN WIDTH TO ACCOMMODATE . (5) WHEN ENGINEERED SHORING IS REQUIRED DUE TO SITE - L "QO 80TH TANKS. THE TANKS MUST BE CONDITIONS AND ENGINEERED SHORING PLAN UTILIZING I 6" ACCESS PORT co W <br /> 1—' <br /> 3'-0" APART MINIMUM (SEE CHART) INTERLOCKING STEEL SHEET PILING SHALL BE PROVIDED AND <br /> w SHALL INCLUDE SUPPORTING ENGINEERING CALCULATIONS BY STAGE I VAPOR RECOVERY 1 <br /> c� A STATE CERTIFIED ENGINEER. <br /> z FIBERGLASS HOLD-DOWN STRAPS ✓ /�,GH A(/ <br /> FURNISHED BY TANK MFR. l yy g E <br /> LOCATIONS. (NUMBER CED AT AAS REQUIRED) ` PRODUCT HDERTIFICATION R CO GRED FOR �• �P'. �A <br /> UPER API STANDARDS. EPDXY MOUNTED <br /> w BALLAST TANK 3 4" WIRE ROPE W/ <br /> O 'A' WITH WATER ONLY NSTALLED <br /> TRIPLE V CLAMP 8" ACCESS PORT <br /> (IF REQUIRED) COVER ENTIRELY W/ TO BE ORIENTATED THIS(AREA TO BY ARCO DISTRIBUTION THIS AREA TO <br /> n. LIBERAL COAT OF TO. THE SAME SIDE y <br /> REMAIN BLACK REMAIN BLACK <br /> ASPHALT CEMENT AS TANK LEVEL GAUGE <br /> ,p 0 <br /> G<rhyo ENO <br /> N4 ROD "HAIRPIN" te2t5.72ND AVENUE olmt <br /> ONE FOR EA. STRAP WHEN DEADMAN _ 8215 72ND AVENU s&32 <br /> Ur •'s• <br /> IS PRECAST OUT (406) 261-6222 <br /> > a 2 3 REBAR <br /> OF THE <br /> HOLE ADD <br /> DN API STANDARD COLORS - <br /> o UNLEADED PREMIUM 92 OCTANE - RED BCE' ---- <br /> W <br /> FU L LENGTH �� EACH COVER (4) UNLEADED 87 OCTANE - WHITE <br /> W/ 2" COVER <br /> as 'G' - UNLEADED PLUS 89 OCTANE - BLUE master release ,date <br /> Q <br /> METHANOL - GREEN <br /> W NO. ARCO . PRODUCTS COMPANY MASTER REVISIONS .. <br /> SEE CHART FOR DEADMAN <br /> z TK3 5 TK3 5NO. DATE _ PREVISIONS PROJECT RELEASE proj. exe. drawn by <br /> D' DIMENSIONS '— 4/20/99 JN. <br /> � - TYPICAL FOR 10' DIAMETER TANKS <br /> PERMIT <br /> project facility <br /> Z. Typical Tank Anchoring Access Cover Identification BID 2186 <br /> z 17 and Connections 18 Standard Two Point Fell CONST. sheet file - <br /> ..^ - TK3-5 <br /> z NOT TO SCALE: NOT TO SCALE; AS-BUILT <br /> of <br /> File: 2023-36A <br /> AR923/92335A.DWG <br />