Laserfiche WebLink
Page G of -�- <br />5. SECONDARY PIPE TESTING <br />Test Method Developed By: ❑ Piping Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ® Pressure ❑ Vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: DIAL GAUGE <br />Equipment Resolution: 0 to 15 psi <br />Piping Run # -�—) <br />PipingRun#qj <br />Piping Run # <br />Piping Run # <br />Piping Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Piping Manufacturer: <br />/ <br />�- <br />Piping Diameter: <br />Length of Piping Run: <br />Product Stored: <br />Method and location of <br />piping -run isolation: <br />�� T <br />\ <br />_ <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />aW� <br />Initial Reading (R,): <br />5 PSI <br />5 PSI <br />5 PSI <br />5 PSI <br />Test End Time: <br />Final Reading (RF): <br />PSI <br />2,12- PSI <br />PSI <br />PSI <br />Test Duration: <br />1 Hour <br />1 Hour <br />1 Hour <br />1 Hour <br />Change in Reading (RF-Rj): <br />C) PSI <br />2 �Z PSI <br />PSI <br />PSI <br />Pass/Fail Threshold or <br />Criteria: <br />Zero <br />Zero <br />Zero <br />Zero <br />Test Result: <br />Pass ❑'Fail <br />❑ Pass JYFail I <br />El Pass ❑ Fail <br />❑ Pass ❑Fail <br />