Laserfiche WebLink
MONITC .NG SYSTEM CERTIFICA'. JN <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6-7,Health and Safety Code;Chapter 16,Division 3 Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: ARCO#02186,CC 18022645 City: STOCKTON CA Zip:95210 <br /> Site Address: 3212 N.CALIFORNIA Contact Phone No: 941-2694 <br /> @ ALPINE AVE. PTO#N-79 Date of Testing/Service: 03/03/2010 <br /> Facility Contact Person: MGR-KEVIN <br /> Make/Model of Monitoring System:V.R.TLS350 R Work Order Number: 2272721 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: T1-87/MAIN Tank ID: T2-87/SYPHO <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: RED JACKET(CPT) Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: T3-911 Tank ID: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: RED JACKET(CPT) Electronic Line Leak Detector. Model: <br /> Tank OverfilUHigh-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> ElOther(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> lspenser Dispenser ID: <br /> Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s) Model: <br /> ❑Shear Valve(s). Shear Valve(s) <br /> E]Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> FIDispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ❑System set-up Alarm history report <br /> Technician Name(print): JOEY MESA Signature: <br /> Certification No.: A27796 License.No.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 11000 N.MoPac Expressway,suite 500,Austin,TX 78759 Date of Testing/Servicing: 03/03/2010 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/08 <br />