COMPLIANCE INFO 2010 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2022 4:35:27 PM
Creation date
3/28/2019 8:40:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN.JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> ARCO 2186 February 22, 2011 <br /> Facility address: UST#/ 4 5 6 <br /> 3212 N California Street, Stockton, CA Product 87 91 87 <br /> Facility contact: Title: Phone: <br /> Kevin Vo Franchisee <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> Veeder-Root TLS-350 ❑XPressunzed❑5uction❑Gravity ❑Mechanical ❑M1-RDetect❑M2-RPrev❑M3-Both <br /> ❑X Audible/visual <br /> Inspection type: Designated operator: ICC exp.date: <br /> ❑X Routine ❑X Monitoring Certification ❑Installation ❑other Justin Abeleda 9-26-11 <br /> On site Service Technician's name: ICC exp.date: Manufacturer's training: <br /> Omar Ruiz 3-3-12 VR 10-18-11, Fastech ELD tester 4-2-12 <br /> # Code Section VIOLATIONS <br /> HSC=CA Health&SafetyCode; CCR=CA Code ofRegulations;ulations;V=Violation; RV=Re eat Violation V V <br /> 1 HSC 25284 No permit tooperate <br /> Secondary containment. (a)test not performed; (e)test report not submitted within 30 days, (f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program (Monitoring&Response Plans is not current or approved by the EHD X <br /> 6 CCR 2712(i) Monitoring Ian, response plan, and/oroperating permit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/2 (M1) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results <br /> of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed (MI) <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST (Mt) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (Mi) <br /> containment <br /> 13 CCR 2636(0(1) Failed to maintain a continuous monitoring system for underground piping& UDCs that activates (Mt) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636( 2 Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi (MI) <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means (M2) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)2 Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping (includes conventional suction piping) (11012) <br /> 21 HSC 25291(e) Water in 21 containment not removed, analyzed&properly disposed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight (Mt) <br /> 22 CCR 2650 hours was not recorded, (e)escaped secondary containment, not cleaned up after eight hours, or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EHD inspector Received by: Title: <br /> EHD 23-02- 2 REV 08113/10 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.