Laserfiche WebLink
Gfrrtea-RYAN INC. GR Job# 10-064011.1 <br /> Appendix VI HECEIVED <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California MAR 0 12016 <br /> Authority Cited:Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations ENVIRONMENTAL <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Arco 2186 Bldg.No.: <br /> Site Address: 3212 N California CityStockton zip: <br /> Facility Contact Person: Contact Phone No.: <br /> Make/Model of Monitoring System: TLS-350 Date of Testing/Servicing: 2124/2016 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicatespecific equipment inspected/serviced: <br /> Tank ID: T-1 Tank ID: T-2 <br /> ® In-Tank Gauging Probe. Model MAG 17 In-Tank Gauging Probe. Model: MAG <br /> D Annular Space or Vault Sensor. Model 794390-409 EK Annular Space or Vault Sensor. Model. 794390-409 <br /> O Piping Sump/Trench Sensor(s), Model 794380.208 I$ Piping Sump/Trench Sensor(s). Model: 794380.208 <br /> D Fill Sump Sensor(s). Model: 794380-208 M Fill Sump Sensor(s). Model: 794380-208 <br /> ❑ Mechanical Line Leak Detector_ Model: ❑ Mechanical Line Leak Detector. Model: <br /> I% Electronic Line Leak Detector Model: 8484-80 ❑ Electronic Line Leak Detector Model: <br /> I% Tank Overfill/High-Level Sensor. Model. VR IX Tank Overfill/High-Level Sensor. Model: VR <br /> ❑ Other(specify equipment a and model in Section E on Pace 2). ❑ Other(specify equipment a and model in Section E on Page 2). <br /> Tank ID: T-3 Tank ID: <br /> M In-Tank Gauging Probe. Model: MAG ❑ In-Tank Gauging Probe. Model: <br /> EK Annular Space or Vault Sensor. Model: 794390-409 ❑ Annular Space or Vault Sensor. Model. <br /> CS Piping Sump/Trench Sensor(s). Model. 794380.208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> CE Fill Sump Sensor(s). Model: 794380.208 ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model <br /> IX Electronic Line Leak Detector Model: 8484-80 ❑ Electronic Line Leak Detector Model: <br /> I% Tank Overfill/High-Level Sensor. Model: VR ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Others eci equipment a and model in Section E on Page- <br /> a e 2. ❑ Other(specify equipment a and model in Section E on Page 2)_ <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> M Dispenser Containment Sensor(s). Model: 794380-208 I% Dispenser Containment Sensor(s). Model: 794380.208 <br /> CK Shear Valve(s). EX Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> EX Dispenser Containment Sensor(s). Model: 794380-208 IX Dispenser Containment Sensor(s). Model: 794380-208 <br /> IX Shear Valve(s) IX Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s) <br /> 'If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment Identified In this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification Is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br /> copy of the report;(check all that apply): ® System set-up ® Alarm history report <br /> Technician Name(print): Tim Adams Signature: <br /> Certification No.: 837367 License.No.: 220793 <br /> Testing Company Name: Gettler-Ryan Inc. Phone No.: 925-551-7555 <br /> Testing Company Address 6805 Sierra Court Suite G, Dublin,Ca.94568 Date of Testing/Servicing: 2/24/2016 <br /> Monitoring System Certification Page 1 of 4 12107 <br /> 1 <br />