Laserfiche WebLink
Time In: <br /> Time Out: <br /> pP.n•�It'!. C San Joaquin County <br /> ).•' '•A <br /> X Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.sjgov.org/ehd <br /> �/FOR <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: ARCO 02186 Date: 02/24/2016 <br /> Address: 3212 N CALIFORNIA , STOCKTON 95204 <br /> Requestor: Telephone (925) 551-7555 <br /> Program Element: 2308-UST RETROFIT Request#: SR0073828 <br /> Inspection Type: 298-UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician Tim Adams ICC Service Tech/Installer Exp. Date: 05/26/2017 <br /> Manufacturer training: Veeder Root, 08/03/17; VMI Tester,08/02/17 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> The following inspections were conducted and witnessed today: <br /> -Sensor functionality testing of the monitoring system after a cold start of the monitoring system and replacement of the UDC <br /> sensors. Passed. <br /> -Leak detector testing at 3gph at 10 psi. Passed. <br /> -Verification testing of electronic overfill prevention. Passed. <br /> -Visual inspection of the piping contained within the UDCs and conversion frames. All piping was contained within the <br /> conversion frames and UDCs. <br /> -Visual inspection of the piping within the dispensers. No leaking was observed. <br /> -Secondary containment testing of the 87 and 91 piping (1 hour at 5 psi). Passed. <br /> -Secondary containment testing of UDC 3/4 (Incon).Passed. <br /> Still needed: <br /> -Primary piping tightness testing on the product lines. The Veeder-Root monitoring panel was programmed for this test(0.1 <br /> gallons per hour)and the test was started while on site. According to the technician, this test must be run for three hours. <br /> .According to Mr. Brian Gan, the technician on site, a cold start of the monitoring panel was performed after a software <br /> upgrade. This cold start was not included in the original permit scope of work. No alarm history was printed prior to <br /> performing the cold start. <br /> "This facility is NOT APPROVED TO OPERATE until passing test results from the primary piping tightness testing are received <br /> by the EHD." <br /> Incon testing certifications: <br /> Brian Gan, ICC x. 7/11/16, Incon x. 6/2/16 <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Brian Gan, Technician <br /> EH Specialist: STACY RIVERA Phone: (209)468-3440 <br /> FA0006773 SR0073828 SC298 02/24/2016 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />