My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2013 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 1:14:19 PM
Creation date
3/28/2019 10:48:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2017
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VEEDER-ROOT <br /> IN STATION DIAGNOSTICS (ISD) <br /> THE KEY TO CALIFORNIA COMPLIANCE VEEDER ROOT <br /> Veeder-Root's California Air Resources Product Components <br /> Board(CARB)certified In-Station <br /> Diagnostics(ISD)system provides the •Assist Vapor Flow Meter—Designed to a <br /> most accurate vapor recovery detection w-tthstand the harsh vapor recovery <br /> environment found in systems with vapor = _ . <br /> available in the industryI4� <br /> vacuum pumps.It provides ISD with the <br /> Veeder-Root's ISD system continuously volume of vapor recovered during vehicle TLS-350 <br /> monitors the vapor recovery equipment, refueling for continuous vapor collection <br /> maintains test records,provides test monitoring <br /> reports,and generates warnings or - A 3 <br /> p g g Balance.Flow Meter —Designed for use <br /> alarms following equipment failure. in pressure sensitive balance systems to Vapor Flow Meter <br /> maintain accuracy and minimize false <br /> The Veeder-Root ISD system can be alarms.It provides ISD with the volume of . <br /> added to any TLS-350 console.This vapor recovered during vehicle refueling for <br /> / <br /> provides you with a cost effective continuous vapor collection monitoring <br /> solution with the Veeder-Root quality <br /> and support that you expect. •Vapor Pressure Sensor —Provides ISD with <br /> tank ullage pressure for vapor containment <br /> The Most Installed ISD Solution <br /> leakage and overpressure monitoring <br /> __.__._.. . <br /> Starting September 2010,ISD is •ISD Software Enhancement Module <br /> ,f <br /> „ required on all gasoline dispensing (SEM)—Unlocks the ISD software in the , <br /> TLS-350 to provide continuous vapor <br /> facilities with an annual throughput over recovery monitoring <br /> 600,000 gallons. Vapor Pressure Sensor <br /> •NV141EM 2 Board —Provides memory <br /> Whether assist or balance vapor expansion necessary for ISD report storage RECEIVED <br /> recovery,over 90%of California <br /> customers have selected Veeder-Roota <br /> ISD system. New stations select the Benefits of the Veeder-Root ISD System DEC 0 9 2015 <br /> Veeder-Root balance ISD solution due to Exceeds Compliance Requirements Cost Effective Solution <br /> simpler nozzle alarm requirements. Me <br /> � NMENTAL <br /> •CARB certified with all approved •ISD OEM can b`" RFPARTAAFNT <br /> Veeder-Root's ISD is the only certified hanging hardware,providing California TLS-350 console,lging ex>sttng <br /> solution that supports all vapor customers with the most options T1S-350 equipment <br /> processor configurations and all certified .Maximizes site uptime using Single •Minimizes initial equipment and <br /> vapor recovery nozzles. Dispenser Shutdown functionality installation costs <br /> Flexible shutdown solutions allows •Flexible ISD solution certified with all •ISD Sensors can share wiring conduit <br /> customers to choose between STP Vapor Processor configurations with other Veeder-Root intrinsically <br /> shutdown,single dispenser shutdown or .CARB certified to meet all ISD performance safe(IS)sensors <br /> use both configurations. requirements as defined by CP201 •Simple installation,compatible with all <br /> including at least a 95%probability of Dispensers <br /> failure detection while operating at no more <br /> than a I%probability of false alarms •Single Dispenser or STP Shutdown <br /> •Continuous monitoring identifies failed <br /> •Wireless option available <br /> vapor recovery equipment during warranty •Veeder-Root warranty for one year from <br /> periods without expensive manual testing date of installation for all new ISD <br /> 00 <br /> •►.. <br /> VEEDER-ROOT components <br />