My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2013 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 1:14:19 PM
Creation date
3/28/2019 10:48:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2017
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWEET INDEX <br /> 0 <br /> SHEET VA c.D L0 O <br /> 1 SITE PLAN / ♦ Ln <br /> 2 DETAILS �/ :t:f r <br /> PROJECT DATA =3 � <br /> PROJECT NAME. ARCO #2186 c; <br /> PROJECT ADDRESS: 3212 N CALIFORNIA STREET, STOCKTON, CA 95204 Ln <br /> CV <br /> FACLRY/PROPEMY BP WEST COAST PRODUCTS, LLC <br /> OWNER 4 CENTERPOINT DRIVE, LA PALMA, CA 90623 <br /> BILDN3CODES 2013 CBC: CALIFORNIA BUILDING CODE <br /> 2013 CMC: CALIFORNIA MECHANICAL CODE <br /> 2013 CPC: CALIFORNIA PLUMBING CODE <br /> 2013 CEC: CALIFrIRNIA ELECTRICAL CODE <br /> 2013 CFC: CALIFORNIA FIRE CODE -tf <br /> 00 <br /> 2013 CALIFORNIA CODE FOR BUILDING CONSERVATION ` :3 (b <br /> 2013 CALIFORNIA EFFICIENCY STANDARDS j LO <br /> 10 <br /> 0 2012 NFPA 30, NFPA 407, NFPA 70, ASCE 7-10 v <br /> SCOPE OF WORK <br /> OA EXISTING (1) 20,000 AND (1) 10,000/12,000 SPLIT GALLON UNDERGROUND STORAGE TANKS TO REMAIN. p <br /> c R 00 :3 <br /> © REMOVE (4) EXISTING DISPENSERS AND VALANCES (DISPOSED: DISPENSERS BY GC, VALANCES BY BP/ARCO). v <br /> I <br /> © REMOVE (1) EXISTING ISLAND (DISPOSED BY BP/ARCO). <br /> 1 �' OD MODIFY (1) EXISTING UNDER DISPENSER CONTAINMENT (UDC) AND FRAME TO MEET ADA REQUIREMENTS. <br /> tIm W <br /> INSTALL (1) NEW 3' X 5' X 13" ISLAND TO MEET ADA REQUIREMENTS. INSTALL 4' X 4' ISLAND AT EXISTING COLUMN, IF <br /> (TYP OF 4) W OE APPLICABLE. <br /> (2) EXISTING 0 INSTALL (4) NEW DRESSER WAYNE OVATION B12 DISPENSERS WITH FACTORY INSTALLED ISD FLOW METERS, CARD READERS, NEW <br /> TANKS A N 0 P Q p p p `J J VST BALANCE VAPOR RECOVERY HANGING HARDWARE AND HIGH HOSE RETRACTORS. INSTALL NEW VALANCES. <br /> VERIFY VEEDER 208 SENSORS IN ALL UDC'S, REPLACE WITH NEW VEEDER ROOT 208 SENSORS IF NECESSARY. <br /> 0 <br /> OH EXISTING PRODUCT AND VAPOR SHEAR VALVES AND FLEX CONNECTORS TO REMAIN. <br /> 1 0 EXISTING VAPOR ASSIST SYSTEM TO BE MODIFIED TO A VST BALANCE VAPOR RECOVERY SYSTEM. <br /> 0 0 20000 ^ R R 1 O 0 <br /> 8INSTALL CAT5 CABLE OR WAYNE TWISTED PAIR FOR MEDIA SCREEN. <br /> R ( ) U U. K ISD SYSTEM TO REMAIN. PROGRAM SOFTWARE TO BE 1.01 VERSION OR GREATER. o <br /> UNLEADED ❑ /E3 <br /> K gaop EXISTING BUILDING © HEALY MOTORS AND VAPOR FLOW METERS TO BE REMOVED AND STORED ONSITE TO BE DISPOSED OF BY BP/ARCO. <br /> p o o N <br /> W <br /> 12,000 I U OM O,N—SITE PAINTING AND DECALING TO BE COMPLETED PER ARCO PAINTING SPECIFICATIONS (P.1.1.). o <br /> / 10,000 <br /> i 92 n <br /> �J 1 87/� I I ON REMOVE EXISTING RED JACKET TURBINE & RED JACKET CONTROL BOXES. <br /> \J �J N <br /> N <br /> \ SUPREME / UNLEADED 00 INSTALL (2) NEW 2 HP FE PETRO TURBINES AND FE PETRO CONTROL BOXES AND ASSOCIATED SOFTWARE. N <br /> CANOPY 9 <br /> �p _ _ — a_—o �1 <br /> I © INSTALL (2) NEW VEEDER—ROOT PLLD (PRESSURIZED LINE LEAs DETECTORS) IN NEW TURBINES. <br /> El0 C D E M ®o ALL TURBINE SUMPS TO BE CLEANED AND ALL STEEL FITTINGS TO BE TREATED WITH CORROSIVE RESISTANT PRODUCT. <br /> } <br /> m <br /> 1 ® EXISTING (2) PIC UNITS TO REMAIN. <br /> O OS RE—START VEEDER—ROOT SYSTEM TO MONITOR EXISTING TANKS AND NEW DISPENSERS. LU <br /> l o <br /> (D START UP, PURGE, AND CALIBRATE ALL SYSTEMS. <br /> l O 0 PERFORM ALL REQUIRED TESTING. <br /> ll � <br /> I <br /> O O <br /> GENERAL NOTES <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT APPLICABLE EDITIONS OF THE CALIFORNIA BUILDING CODE, CALIFORNIA <br /> — — — / PLUMBING CODE, CALIFORNIA MECHANICAL CODE, CALIFORNIA FIRE CODE, CALIFORNIA ELECTRICAL CODE, CAL—OSHA CONSTRUCTION <br /> SIDEWALK SAFETY ORDERS, AND ALL OTHER APPLICABLE STATE, CITY AND COUNTY ORDINANCES. <br /> DRIVEWAY DRIVEWAY <br /> 2. CONTRACTOR IS RESPONSIBLE FOR CONTACTING UNDERGROUND SERVICE ALERT (USA) 1-800-227-2600 OR 811 AT LEAST 2 <br /> WORKING DAYS PRIOR TO THE START OF WORK <br /> 3. THE INFORMATION REGARDING THIS SITE PLAN WAS OBTAINED FROM AN EXISTING ARCO GROUND PLAN. THE CONTRACTOR SHALL <br /> VERIFY THE EXISTING SITE CONDITIONS AND VERIFY ALL SITE WORK TO BE DONE PRIOR TO BID SUBMITTAL. IN THE EVENT OF A <br /> CONFLICT, THE CONTRACTOR SHALL NOTIFY THE COMPANY REPRESENTATIVE BEFORE PROCEEDING WITH ANY WORK. <br /> E ALPINE AVENUE 4. ALL DIMENSIONS AND CONDITIONS SHALL BE CHECKED AND VERIFIED IN THE FIELD BEFORE BIDDING. ANY DISCREPANCIES SHALL BE <br /> CALLED TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE FOR HIS/HER DECISION PRIOR TO FINALIZING BIDS AND START OF I j <br /> WORK. LAJ s <br /> 5. CONTRACTOR SHALL PROTECT ALL EXISTING FACILITIES, BOTH PUBLIC AND PRIVATE, WHICH ARE TO REMAIN UNLESS NOTED Z <br /> F— <br /> OTHERWISE. CONTRACTOR SHALL REPAIR OR REPLACE, TO THE OWNER'S SATISFACTION, ANY EXISTING FACILITIES WHICH ARE V) <br /> DAMAGED AS RESULT OF CONTRACTOR'S OPERATIONS. Lil Q O o <br /> 6. ALL WORK AREAS SHALL BE ADEQUATELY BARRICADED THROUGHOUT THE CONSTRUCTION PERIOD. Q Z LC') <br /> SITE PLAN I _j 0 rn <br /> SCALE: 1" = 20'-0" Z 7. CONTRACTOR SHALL OBTAIN NECESSARY PERMITS FROM APPLICABLE AGENCIES FOR EXCAVATIONS OF TRENCHES 5'-0" OR MORE IN_ DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND. L� C:) <br /> Q <br /> I U <br /> 8. CONTRACTOR TO PERFORM ALL REQUIRED VAPOR RECOVERY TESTWC PER CARE VR-204 AND LOCAL AIR POLLUTION CONTROL z 00 J o <br /> AUTHORITY AND FORWARD RESULTS TO OWNER AND JURISDICTION AS SPECIFIED IN THE PERMIT CONDITIONS. <br /> BILL (DF MATERIALS o to 20 40 so <br /> QTY. SPECIFICATION 9. ALL MATERIALS SHALL BE COMPATIBLE FOR USE WITH THE INTENDED PURPOSE PER NATIONALLY RECOGNIZED CODES, LOCAL CODES 0 2 <br /> PART DESCRIPTION AND GOVERNING AUTHORITIES. CLY <br /> "OVATION" H-FRAME BLENDING MULTI-PRODUCT DISPENSER: 3-GRADE, 2-SIDED, 1 HOSE PER SIDE, WITH FACTORY 4 WAYNE OVATION SERIES #8 10. FUELING SYSTEM TO BE INSPECTED PER LOCAL REGULATING AGENCIES AND BY OWNER'S REPRESENTATIVE PRIOR TO BEING PLACED-12 (3+0) GASOLINE ONLY SCALE: 1 °= 20' w W(/) O <br /> M <br /> 01 INSTALLED ISD FLOW METERS, CARD READER OPTIONS, CONFIGURED AS REQUIRED FOR SITE SPECIFIC CONDITIONS � U �O cC14 U <br /> BACK INTO SERVICE. Cif IN F— <br /> AND MARKETS. FOR ISLAND—LESS SOLUTION ORDER 6" PEDESTAL -- WAYNE OVATION SERIES 888531 LEGEND <br /> 11. TANK SYSTEM, LEAK DETECTORS AND MONITORING SYSTEM INTEGRITY TESTS SHALL BE FORWARDED TO AND APPROVED BY GOVERNING <br /> 02 BRAVO SYSTEMS CONVERSION FRAME FOR NON—BRAVO UDC 4 CONV-82000—OPP AGENCY PRIOR TO TANK SYSTEM BEING PLACED INTO OPERATION (AS APPLICABLE). <br /> (E) EXISTING <br /> 3 G2 BLACK EVR BALANCE SYSTEM NOZZLE (N) NEW NEW ELECTRICAL LOADS WILL BE INTRODUCED AS A RESULT OF THIS PROJECT. DRAWN BY: CK <br /> 8 VST #VST—EVR—NB—BK-2 12. NO <br /> 0 ESO EMERGENCY SHUT—OFF REVIEWED BY: LM 12 <br /> 12 <br /> ® 1-1/2" DIAMETER FIREFLEX CONNECTOR WITH 1-1/2" MALE X 1/1-2" MALE SWIVEL 18" LENGTH 12 FF15X18NMXM346 13. ALL ELECTRICAL FITTINGS TO BE CLASS 1 DIVISION 1 RATED DATE: 11/23/2015 <br /> 0 EVR BALANCE VR HOSE — 8' MAXXIM PREMIER PLUS WITH 30-32 INCH VENTURI 1. <br /> 8 GOODYEAR — EVR SERIES #53236564108031 AQMD INFORMATION JOB N0: 40-015058.1 <br /> VICINITY MAP <br /> © BALANCE VR HOSE — 6' MAXXIM PREMIER (WITHOUT VENTURI) 8 GOODYEAR — EVR SERIES #53236544000600 _ <br /> NUMBER OF (E) FUELING STATIONS 8 <br /> 7 REATTACHABLE SAFETY BREAKAWAY 8 VST #VSTA—EVR—SBKA NUMBER OF (E) GASOLINE NOZZLES 8 <br /> ® <br /> 1 VEEDER—ROOT #330020-515 (1 PER SITE) NUMBER OF (N) FUELING STATIONS 8 <br /> VAPOR PRESSURE SENSOR ISD/PMC <br /> NUMBER OF (N) GASOLINE NOZZLES 8 <br /> 9 COAXIAL HOSE CLAMP 8 GOODYEAR — #8109 C� T s <br /> 0 NUMBER OF (N) DIESEL NOZZLES 0 SITE E HF ENVIRONMENTAL <br /> o <br /> HEALTH nFPARTANENT <br /> 10 DISPENSER DATA/CRIND/CREDIT CARD DISCONNECT 1 POWER INTEGRITY #DDS-8DM4GE <br /> 11 DISPENSER INTERCOM DISCONNECT 1 POWER INTEGRITY DDS-8DB4C <br /> # IMPORTANT NOTICE 'F <br /> 12 PIPING SUMP SENSOR 12 FOOT CABLE 4 VEEDER—ROOT #794380-208 Section 4216/4217 of the Government <br /> o <br /> O Code requires a Dig Alert Identification SHEET <br /> 3 10 MICRON HIGH PERFORMANCE Bio—TEK FILTER — 1 INCH FLOW 8 400MB-10 Number be issued before a <br /> Permit r Excavate Will re valid U • <br /> 1 5' L X 36" W X 13" H, W/ 6" RADIUS STRAIGHT ENDS #515-5-36—RR For your Dig Alert ID Number Call S <br /> 14 ISLAND FORMS UNDERGROUND SERVICE ALERT w�� <br /> 2 ISTK-2/ISTKR-2 A — 9 <br /> 15 INTELLIGENT SUBMERSIBLE TURBINE PUMP 2HP VARIABLE SPEED AND RISER 1 -800-227-2600 <br /> or 811 <br /> 16 PRESSURIZED LINE LEAK DETECTOR WITHOUT SWIFT CHECK VALVE 2 848480-001 J <br /> For Underground Locating <br /> 7 SIPHON CHECK VALVE 1 400137937 2 Working Days before You Dig �F 2 SHEETS <br />
The URL can be used to link to this page
Your browser does not support the video tag.