My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2013 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 1:14:19 PM
Creation date
3/28/2019 10:48:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2017
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9255517888 Line 15:00:55 01-14-2014 2/8 <br /> ®GETTL FR-RYAN INC. Gm Job # -14 20-512f714 �`°� <br /> Appendix VI i, <br /> MONITORING SYSTEM CERTIFICATION JAN 14 70'4 <br /> For Use By All Jurisdictions Within the State of California +-- _fa r;ry , �. ,� <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of +4�L. <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Arco 2186 Bldg.No.: <br /> Site Address: 3212 N California St City: Stockton zip: <br /> Facility Contact Person: Contact Phone No.: <br /> Make/Model of Monitoring System: VR TLS35OR Date of Testing/Servicing: 12119/2013 <br /> B. Inventory of Equipment Tested/Certified <br /> Check theappropriate boxes to indicatespecific equipment inspected/serviced: <br /> TanklD: 1-87 TanklD: 2-87 <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> 1K Piping Sump/Trench Sensor(s). Model: 794380.208 ® Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> 1$ Fill Sump Sensor(s). Model: 794380-208 © Fill Sump Sensor(s). Model: 794380-208 <br /> E7 Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment a and model in Section E on Page 2). ❑ Other(specify equipment t e and model in Section E on Page 2). <br /> TanklD: 3-91 TanklD: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 794380-208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ® Fill Sump Sensor(s). Model: 794380-208 ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment and model in Section E on Page 2). ❑ Other(specify equipment a and model in Section E on Page 2). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dis enser Containment Floats and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s)- <br /> Dispenser ID: <br /> hains.DispenserlD: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> .If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility_ <br /> C. Certification - I certify that the equipment identified in this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, 1 have also attached a <br /> copy of the report;(check all that apply): ❑ System set-up ® Alarm history report <br /> Technician Name(print): Chris SanNICOIas Signature: <br /> Certification No.: 633787 License.No.: 220793 <br /> Testing Company Name: Gettler-Ryan Inc. Phone No.: 925-551-7555 <br /> Testing Company Address: 6747 Sierra Court Suite J, Dublin, Ca.94568 Date of Testing/Servicing: 12/19/2013 <br /> Monitoring System Certification Page 1 of 4 12/07 <br /> ) <br /> Received Time Jan, 14, 2014 1 : 53PM No. 5018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.