San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.or./q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO 02186 3212 N CLIFORNIA ST, STOCKTON January 05, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 315 HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> Liquid was observed in UDC 7/8. If water could enter into the secondary containment by precipitation or infiltration, <br /> it must be removed and disposed of properly. The service technician removed approximately one inch of liquid from <br /> the UDC sump. Ensure that all sumps and annular spaces are maintained free of liquid. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 4, 2016. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Documents reviewed: CERS submittals, designated operator monthly inspection reports, designated operator <br /> training logs <br /> Documents provided: Return to Compliance Certification form, Schedule of free CUPA classes <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: January 05, 2017 Inspector: Inspector Phone: <br /> Printed Name and Title: STACY RIVERA, Senior REHS (209) 468-3440 <br /> Ronald Vo, Worker <br /> FA0006773 PR0231035 SCO01 01/05/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 4 Underground Storage Tank Program OIR <br />