My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2013 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 1:14:19 PM
Creation date
3/28/2019 10:48:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2017
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page_2_of—7- <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑ Pressure ®Vacuum ❑ Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: 0-30"VACUUM GAUGES Equipment Resolution: .5% <br /> rnter : a a s, 2&1:- r, <br /> Tank#87(1) Tank#87(2)/91 Tank# Tank# <br /> Is Tank Exempt From Testing?' ❑Yes ®No ❑ Yes ®No ❑ Yes ❑No ❑ Yes ❑No <br /> Tank Capacity: 20000 20000 <br /> Tank Material: FIBERGLASS FIBERGLASS <br /> Tank Manufacturer: XERXES XERXES <br /> Product Stored: 87 87191 <br /> Wait time between applying <br /> pressure/vacuum/water and 10 MIN 10 MIN <br /> starting test: <br /> Test Start Time: 10:00 10:00 <br /> Initial Reading(R,): 10" 10" <br /> Test End Time: 12:00 12:00 <br /> Final Reading(RF): 10" 10" <br /> Test Duration: 2 HR 2 HR <br /> Change in Reading(RF-R,): 0 0 <br /> Pass/Fail Threshold or Criteria: NO LOSS NO LOSS NO LOSS NO LOSS <br /> Test Result: ®Pass ❑ Fail ® Pass ❑ Fail ❑Pass ❑ Fail ❑ Pass ❑ Fail <br /> Was sensor removed for testing? Elves ❑No [:INA ®Yes [-]No ❑NA [:]Yes ❑No ❑NA []Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? <br /> ®Yes ❑No ❑NA ®Yes [—]No ❑NA ❑Yes ❑No ❑NA ❑Yes [--]No ❑NA <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 87(2)AND 91 IS A DUAL COMPARTMENT/SPLIT TANK WITH A SINGLE SHARED ANNULAR SPACE <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.