My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 1:29:09 PM
Creation date
3/28/2019 2:24:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
im6ETTim-RyAti kc. GR Job # 18200384 <br /> SWRCB,January 2002 Page 4 of 4 <br /> 8.FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are Present,but were Not Tested <br /> Test Method Developed By: Tank Manufacturer Industry Standard Professional Engineer <br /> Other(specify) <br /> Test Method Used: Pressure Vacuum Hydrostatic <br /> Other(s eci <br /> Test Equipment Used: ]neon t2uipment Resolution: 0.0001 <br /> _s. s:. 3 Fill Sum # 91 Fill Sump# 87.2 Fill Sump# Fill Sum # <br /> Sump Diameter: 42" 42" <br /> Sump Depth: 53" 53" <br /> Height from Tank Top to Top of <br /> bottom bottom <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 30" 30" <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> Fair Fair <br /> testing: <br /> Portion of Sump Tested(1) 34" 34" <br /> Sump Material: Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 15 mins 15 mins- <br /> starting test: <br /> Test Start Time: 11:36 AM 11:36 AM <br /> Initial Reading(Ri): 4.8275 5.3748 <br /> Test End Time: 11:51 11:51 <br /> Final Reading(Rf) 4.8270 5.3745 <br /> Test duration: 15 Mins 15 Mins <br /> Change in Reading(Rf-Ri): 0.0005 0.0003 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Results: Fail EQ Fail Pass Fail Pass Fail <br /> Is there a sensor in the sum ? Yes No Yes No Yes No Yes No <br /> Does the sensor alarm when <br /> either product or water is Yes No NA Yes No NA Yes No NA Yes No NA <br /> detected? <br /> Was sensor removed for testing? Yes No NA Yes No NA Yes No NA Yes No NA <br /> Was sensor properly replaced and ye No NA Yes No NA Yes No NA Yes No NA <br /> verified functional after testing? <br /> Comments-(include information on repairs made prior to testing, and recommend follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.