My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 1:29:09 PM
Creation date
3/28/2019 2:24:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
®&TTLER-9YAN INC. GR Job# 17204467 <br /> Appendix VI SWRCB,January 2006 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of Califomia <br /> Authority Cited; Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Arco 2186 Bldg.No.: <br /> Site Address: 3212 N. Califomia City: Stockton Zip: 95204 <br /> Facility Contact Person: Daryl Lee Contact Phone No.: 415.902.5089 <br /> Maka/Model of Monitoring System: TLS-350 Date of Testing/Servicing: 1/3/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicate specific 2quipment Ina tedlserviced: <br /> Tank ID: 87-1 Tank ID: 87-2 <br /> In-Tank Gauging Probe. Model: 847390-109 m Irl-Tank Gauging Probe. Model: 847390-Ing <br /> Annular Space or Vault Sensor. Model: 7 94 3 9 0-4 0 m Annular Space or Vault Sensor. Model: <br /> — —� 194Piping Sump/Trench Sensar(s). Model: 794380-20$ m Piping Sump!Trench Sensor(s). Madel:l8Fill SumpSensor(s). Model: 794380-208 m Fill SumpSensor(a). Model: 794380-2Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector Model: 848480 ❑ Electronic Line Leak Detector Model: <br /> Tank Overfill/High-Level Sensor. Model: VR @ Tank Overfill/High-Level Sensor. Model. VR <br /> Others a ui ment and model in Section E on P e 2. ❑ Others ui ment and model in Section E oh Pa 6"2 <br /> TanklD: 9 1 TanklD: <br /> In-Tank Gauging Probe. Model: 847390-109 ❑ In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: - ❑ Annular Space or Vault Sensor. Model: <br /> i Piping Sump/Trench Sensor(s). Model: - ❑ Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensogs). Model: 794T8_07208 ❑ Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> i Electronic Line Leak Detector Model: 848480 ❑ Electronic Line Leak Detector Model: <br /> Tank Overfill/High-Level Sensor. Model; VR ❑ Tank Overfill/High-Level Sensor, Model: <br /> Others equipment and model in Section E on Pape 2). ❑ Others equipment and model in Section E on Pa e 2). <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> Dispenser Containment Sensor(s). Model: 794380-208 ❑ Dispenser Containment Sensor(s) Model: 794380-208 <br /> i Shear Valve(s). G3 Shear Valve(s). <br /> Dispenser Containment FI s and Chain(s) ❑ Dispenser Containment Floa s and Chain(s). <br /> Dlepenser ID: 5/6 [DlapensorID: 7/8 <br /> Dispenser Containment Sensor(s). Model: 794380-208 Dispenser Containment Sensors). Model: 794380-208 <br /> Shear Valve(s). Shear Valve(s). <br /> Dis nser Containment Floa s and Chains. Dis nser Containment Float(s)and Chain(s). <br /> DispenserlD: Dispenser 10: <br /> Dispenser Containment Sensor(s). Moder: ❑ Dispenser Containment Sensors), Model: <br /> Shear Valve(s). ❑ Shear Valve(s). <br /> Dispenser Containment Float(s) and Chains. ❑ Dispenser Containment Floats and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment Identified In this document was inspected/serviced In accordance with the manufacturers' <br /> guidelines. Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verify that this information Is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a <br /> copy of the report;(check all that apply): [Z] System set-up Q Alarm h� <br /> �` _ <br /> Technician Name(print): Alexander Tato Signature: <br /> Certification No.: B42662 License.No.: 220793 <br /> Testing Company Name: Gettler-Ryan Inc. Phone No.: 925-551-7555 <br /> Testing Company Address: 6806 Sierra Court Suite G.,Dublin CA 94568 Date of Testing/Servicing: 1/3/2018 <br /> Monitoring System Certification Page 1 of 4 12/07 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.