Laserfiche WebLink
• PquiN San Joaquin County <br /> �O,• '" •.C'0 DIRECTOR <br /> Environmental Health Department Linda Turkatte, REHS <br /> .Z 1868 E Hazelton Avenue <br /> Stockton California 95205 PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, RENS, RDI <br /> ORN Kasey Foley, REHS <br /> Website: www.sjcehd.com Adrienne Ellsaesser, REHS <br /> Phone: (209)468-3420 Rodney Estrada, REHS <br /> Fax: (209)464-0138 <br /> RE: Well Pump Inspection <br /> Well Location: Permit#: SR00')�-(..5�- Inspection Date: 2 <br /> The Environmental Health Department recently conducted a water well pump inspection at the above <br /> address and found the following issues at the time of the inspection. In order to protect the ground water <br /> supply and your water source from potential degradation, please take the associated corrective actions. <br /> 0 Lack of or Inadequate Concrete Platform around Wellhead. <br /> (SJC Water Well Standards, Section 4.10. —Surface Seal) <br /> Corrective Action: Repair existing or install a new concrete platform around the wellhead. <br /> O Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code,Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> O Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> O Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> O Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end of <br /> the pipe. Air Vent-extend pipe 12 inches above with end inverted in a downward direction and <br /> covered with 16-mesh screening. <br /> O Excessive Vegetation or debris around Wellhead. <br /> (SJC Ord. Code, Section 9-1115.4.—Dangerous/Nuisance) <br /> Corrective Action: Remove and maintain debris and vegetation away from well area. <br /> O Other <br /> If you have any questions please call/t s uUqsl,�Sr. R.E.H.S. at ( <br /> Rodney Estrada, R.E.H.S. <br /> Program Coordinator <br />