Laserfiche WebLink
March 2, 2021 Lab ID : STK2131947 <br /> San Joaquin Co. Environmental Health Dep Customer : 3-17919 <br /> Quality Control-Inorganic <br /> Constituent Method Date/ID Type Units Cone. QC Data DQO Note <br /> Wet Chem <br /> Nitrate 300.0 (CH 2170944-005) MSD mg/L 40.00 100% 85-119 <br /> MSRPD m 10.00 0.6% <19 <br /> 300.0 02109/21:202017MCA CCB mg/L 0.000 0.5 <br /> CCV mg/L 20.00 97.8% 90-110 <br /> CCB mg/L 0.000 0.5 <br /> CCV m 20.00 97.6% 90-1 l0 <br /> Nitrate+Nitrite as N 300.0 02/09/21:201408MCA Blank mg/L ND <0.1 <br /> Nitrate Nitrogen 300.0 02/09/21:201408MCA Blank mg/L ND <0.1 <br /> Nitrite 300.0 02/09/21:201408MCA Blank mg/L ND <0.5 <br /> LCS mg/L 15.00 101% 90-110 <br /> MS mg/L 30.00 101% 74-126 <br /> (CH 2170944-001) MSD mg/L 30.00 103% 74-126 <br /> MSRPD mg/L 10.00 1.7% 520 <br /> MS mg/L 30.00 102% 74-126 <br /> (CH 2170944-005) MSD mg/L 30.00 104% 74-126 <br /> MSRPD mg/L 10.00 1.4% :520 <br /> 300.0 02/09/21:202017MCA CCB mg/L 0.000 0.5 <br /> CCV mg/L 15.00 101% 90-110 <br /> CCB mg/L 0.000 0.5 <br /> CCV m 15.00 103% 90-110 <br /> Nitrite Nitrogen 300.0 02/09/21:201408MCA Blank mg/L ND <0.2 <br /> Sulfate 300.0 02/09/21:201408MCA Blank mg/L ND <0.5 <br /> LCS mg/L 50.00 104% 90-110 <br /> MS mg/L 100.0 96.8% 82-124 <br /> (CH 2170944-001) MSD mg/L 100.0 98.4% 82-124 <br /> MSRPD mg/L 10.00 1.3% <23 <br /> MS mg/L 100.0 98.4% 82-124 <br /> (CH 2170944-005) MSD mg/L 100.0 99.3% 82-124 <br /> MSRPD mg/L 10.00 0.8% :523 <br /> 300.0 02/09/21:202017MCA CCB mg/L 0.132 0.5 <br /> CCV mg/L 50.00 101% 90-110 <br /> CCB mg/L 0.133 0.5 <br /> CCV mg/L 50.00 101% 90-110 <br /> MBAS 5540C 02/10/21:202358jba CCB mg/L -0.0400 0.25 <br /> CCV mg/L 1.000 102% 90-110 <br /> CCB mg/L -0.0400 0.25 <br /> CCV m 1.000 102% 1 90-110 <br /> MBAS Extraction 5540C 02/10/21:201755jba Blank mg/L ND <0.1 <br /> LCS mg/L 0.5000 101% 86-114 <br /> BS mg/L 0.5000 91.8% 86-114 <br /> BSD mg/L 0.5000 89.4% 86-114 <br /> BSRPD mg/L 0.5000 0.012 <_O.I <br /> Definition <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> BS :Blank Spikes-A blank is spiked with a known amount of analyte.It is prepared to verify that the preparation process is not <br /> affecting analyte recovery. <br /> Page 8 of 9 <br />