o <br /> 21 <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 TANKS <br /> 4 <br /> VI.PIPING CONSTRUCTION(Ghee all thaia Page 2.of 2 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TITE 911.PRESSURE ❑2.SUCTION ❑3.GRAVITY 458 ❑1.PRESSURE ❑2. SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCnoN ❑L SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460 ❑).SINGLE WALL ❑95.UNKNOWN 462 <br /> MANUFALTURER 912.DOUBLE WALL ❑95.UNKNOWN ❑2.DOUBLE WALL_ ❑99.OTHER <br /> MANUFACTURER SMITH FIBERGLASS 461 MANUFACTURER 463 <br /> ❑1.BARE STEEL 916.FRP COMPATIBLE whorl% METHANOL. 111-BARE STEEL ❑6.FRP COMPATIBLE wn009/Mr HAN01. <br /> ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑UrAnown ❑2. STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> ❑3.PLASTIC COMPATIBLE W/CONTENTS ❑99.Other ❑3. PLASTIC COMPATIBLE W/CONTENTS ❑8.FLEXIBLE(HDPE) ❑99.OTHER <br /> ❑4.FIBERGLASS ❑8.FLEXIBLE(HDPE) ❑4. FIBERGLASS ❑9.CATHODIC PROTECTION <br /> ❑S.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5. STEEL W/COATING ❑95.UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check a0 that (A dexcriptian ofLbcmoniwnng prognm shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVBGROUND PIPING <br /> SINGLE WALL PIPING 4M SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ <br /> AUDIBLE AND VISUAL ALARMS. AUDIBLE AND VISUAL ALARMS. <br /> ❑2.MONTHLY 0.2 GPH TEST ❑2. MONTHLY 0.2 GPH TEST <br /> ❑3.ANNUAL INTEGRITY TEST(0.1 GPH) ❑3.ANNUAL INTEGRITY TEST(0.7 GPH) <br /> [14. DAELY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Cheek all that apply) <br /> ❑ <br /> S.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING <br /> INTEGRITY TEST(0.1 GPH) ❑5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): ❑6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> ❑7.SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW ❑7. SELF MONITORING <br /> ❑9.BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> ❑8. DAILY VISUAL MONITORING <br /> ❑9.BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check a0 that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSORJET ii AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Cheek one) <br /> ❑a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ®b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> ❑c.NO AUTO PUMP SHUT OFF ❑c NO AUTO PUMP SHUT OFF <br /> ®11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT <br /> OFF OR RESTRICTION ❑11.AUTOMATIC LEAK DETECTOR <br /> ®12. ANNUAL INTEGRITY TEST(0.1 GPH) [112.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑14.CONTINUOUS SUMP SENSOR WITH AUTO PUMP SHUT OFF' ❑14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF' <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION ❑15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH)EST) <br /> ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑17. DAILY VISUAL CHECK ❑17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ®2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑5.TRENCH LINER/MONITORING <br /> 2003 ❑3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS ❑6.NONE 469 <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I cmify that the info tion provided herein is true and acetmate to the best of my knowledge. <br /> SIGNA OWNER/OPERATOR DATE 470 <br /> NAME OF-OVINMOPRATOR(print) 471 TIME OF OPERATOR 472 <br /> KAREN DHINGSA FACILITY MANAGER <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) 474 Penn:;6_nirntion Dam(F---is only) 475 <br /> UPCF(12/99 revised) 12 Formerly SWRCB Form B <br />