Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 <br /> (two pages per tank) ./ <br /> Page IL of e <br /> TYPE OF ACTION ❑1.NEW SITE PERMIT ❑ 4. AMENDED PERMIT /, C"ANGE OF INFORMATION) ❑ 8. TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7. PERMANENTLY CLOSED ON SITE <br /> ❑3.RENEWAL PERMIT (Specify mason-/or local use only) (Specify change-for local use only) ❑ 8. TANK REMOVED 430 <br /> BUSINESS NAME(Samee'as FACILITY NAME or DBA- g Bwiness As) FACILITY ID# <br /> LOCATION VATFV SITE(Option I) 431 <br /> c . Z <br /> I.TANK DESCRIPTION <br /> TANK ID# �f TANK JANI.LFACTURER COMPARTMENTALIZED TANK ❑ Yes 1K. <br /> �f-1 _ A . If"Yes',complete one page for each compartment. <br /> b Ix ow )a <br /> DATE INSTALLED(YEAKIMO) TANK CAPACITYIN GALLONS NUMBER OF COMPARTMENTS "l l <br /> 6 - IIS o/� <br /> ADDITIONAL DESCRIPTION(For local use only) <br /> II.TANK CONTENTS <br /> TANK USE 432 PETROLEUM TYPE <br /> ❑ 1. MOTOR VEHICLE FUEL ❑1�. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br /> (it marked,complete Petroleum Type) 1b. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑99. OTHER <br /> ❑ 3.CHEMICAL PRODUCT <br /> COMMON NAME(hom Hazardous Materials Inventory page) CAS#(from Hazardous Materials Inventory page) <br /> ❑ 4. HAZARDOUS WASTE(Includes <br /> Used Oiq <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br /> (Check one item only) ❑ 2. DOUBLE WALL EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ❑ 4. SINGLE WALL IN A VAULT ❑99 OTHER <br /> TANK MATERIAL-primary tank ❑ 1 BARE STEEL ❑ 3. FIBERGLASS/PLASTIC ❑ 5. CONCRETE ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE W/100%METHANOL ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑ 1 BARE STEEL ❑ 3. FIBERGLASS/PLASTIC ❑ 8. FRP COMPATIBLE WI100%METHANOL ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑ 5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑95. UNKNOWN433 DATE INSTALLED <br /> OR COATING <br /> ❑ 2. ALKYD LINING ❑ 4. PHENOLIC LINING ❑ 8. UNLINED ❑99. OTHER <br /> Check one item on i For local use only) <br /> DATE INSTALLED <br /> OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC ❑ 3. FIBERGLASS REINFORCED PLASTIC C195. UNKNOWN 434 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑ 4. IMPRESSED CURRENT [:399. OTHER <br /> (Check one item only) ❑ 2. SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(For local use only) OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED <br /> (Check all that apply) ❑ 1 SPILL CONTAINMENT ❑ 1.ALARM ❑ 3. FILL TUBE SHUT OFF VALVE <br /> ❑ 2. DROP TUBE ❑ 2. BALL FLOAT ❑ 4. EXEMPT <br /> ❑ 3. STRIKER PLATE <br /> IV. TANK LEAK DETECTION <br /> IF SINGLE WALL TANK(Check all that apply): IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item only): <br /> ❑ 1, VISUAL(EXPOSED PORTION ONLY) ❑ 5. MANUAL TANK GAUGING(MTG) ❑ 1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 2. AUTOMATIC TANK GAUGING(ATG) ❑ 6. VADOSE ZONE ❑ 2. CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 3. CONTINUOUSATG ❑ 7. GROUNDWATER ❑ 3. MANUAL MONITORING <br /> ❑ 4. STATISTICAL INVENTORY RECONCILIATION(SIR)+ ❑ 8. TANK TESTING <br /> BIENNIAL TANK TESTING ❑99, OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YRIMO/DAY) ESTIMATED QUANTITY OF SUBSTANCE REMAINING 435 1 TANK FILLED WITH INERT MATERIAL? <br /> gallons C]Yes ❑No <br /> CUPAFORM(4/99) Formerly SWRCB Form B <br />