Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> VI.PIPINCs CONSTRUCTION(Check ap that appfA <br /> ABOVEGROUND PIPING <br /> UNDERGROUND PIPING ❑ 2. SUCTION ❑ 3. GRAVITY <br /> SYSTEM TYPE ❑ 1 PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE <br /> ❑95. UNKNOWN <br /> CONSTRUCTION/ [I1. SINGLE WALL ❑ 3. LINED TRENCH ❑99. OTHER ❑ 1. SINGLE WALL ❑99 OTHER <br /> ❑ 2. DOUBLE WALL - <br /> MANUFACTURER ❑ 2. DOUBLE WALL ❑95- UNKNOWN MANUFACTURER <br /> MANUFACTURER ❑ S. FRP COMPATIBLE W1 100%METHANOL <br /> ❑ 1.BARE STEEL ❑ 6. FRP COMPATIBLE W1100%METHANOL ❑ 1. BARE STEEL ❑ 7 GALVANIZED STEEL <br /> MATERIALS AND [12. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> C12. STAINLESS STEEL <br /> CORROSION ❑ 3 PLASTIC COMPATIBLE HATH CONTENTS ❑95. UNKNOWN ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ 8. FLEXIBLE(HDPE) <br /> 99. OTHER <br /> PROTECTION ❑ 9.CATHODIC PROTECTION <br /> ❑ 4. FIBERGLASS ❑ 8. FLEXIBLE(HDPE) 1199. OTHER ❑ 5. STEEL L COATING [195. UNKNOWN <br /> ❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION <br /> VII.PIPING LEAK DETECTION(CheckaBthetappty) <br /> ' ABOVEGROUND PIPING <br /> UNDERGROUND PIPING SINGLE WALL PIPING <br /> SINGLE WALL PIPING PRESSURIZED PIPING(Check all that apply): <br /> PRESSURIZED PIPING(Check all that apply): PUMP <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1 SYSTEM FAIL <br /> C LINE ALARMS <br /> AND SYSTEM LEAK TDISCO NECTION WITH AUTO <br /> EOAND V SUAL ALARMS LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ❑ 2 MONTHLY IL GPH TEST <br /> ALARMS <br /> ❑ 2. MONTHLY 0.2 GPH TEST ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> CONVENTIONAL SUCTION SYSTEMS: ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> ❑ 5 DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOWGRAVITY FLOW(Check all that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING PRESSURIZED PIPING(Check all that apply): <br /> PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND V,SUAL ALARMS AND(check one) <br /> (Check one) <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b. AUTO PUMP SHUT OFF FOR LEAKS.SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) C112. ANNUAL INTEGRITY TEST(0 t GPH) <br /> SUCTIONIGRAVITY SYSTEM: SUCTIONIGRAVITY SYSTEM: <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check as that appM <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT ALTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPM) <br /> ❑ 'IT DAILY VISUAL CHECK ❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED ❑ 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND. __=_-_== 5 ❑ S. TRENCN <br /> L y VONITORING <br /> ❑ 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO S'••______-__=E,qER+AUDIBLE AND V;-- <br /> El 6. NONE <br /> OL CVV%E1L0PEC- �S.-SVATURE <br /> I certify that the information provided herein is true and accurateto the best of my know+ecye <br /> SIGNATURE OF OWNER/OPERATOR - <br /> NAME OF OWNER/OPERATOR(pont) TITLE CF *.E:7PERATOR <br /> Permit dumber(For local use only) Permit Approved(For local use or)ynll Penna Expiration Date(For local use only) <br /> V <br /> CUPAFORM(4/99) <br /> Formerly SWRCB Form B <br />