Laserfiche WebLink
JAN .10.2013 9:23PM CORNELIUS NO.8- <br />EIVE'D <br />Appendix Vi JAN 10 2013 <br />(COPles of Monitoring System Certiflcation form and UST Monitoring Plot Plan available at htt :(hhrAW t QTAL <br />TEM CERTIFICATIONMONITORING SYS NT <br />For Uso By All Jur4sdiojioris Wthir, the State <br />of Californila <br />Authority Cited: Chapter 6.7, Heaith and Safety Code; Chapter 16,Division 3, Title 23, California Code Of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who pertorms the work. A Copy of this €oral must be provided to the tank system <br />Owner/eperator, The owner/operator must submit a copy of this form to the Iocai agency regulating UST systems within 30 days of test date. <br />A. Generallnformation <br />Facility Name; FLAGE CITY CHEVRON Bldg, No.: <br />SilsAddress: 6421 CAPITAL <br />Facility Contact Person: PAT MULHALL <br />MekolModel of Monitoring Sy&tem: VEEDER ROOT TLS 350 <br />B, inventory of Equipment Tested/Certified <br />Check the aepropriate boxes to Indicate _specific _no <br />Tank ID; 1 SUPRF-ME <br />X In -Tank Gauging Probe, <br />Model- VR MAG PROS <br />X Annular Space or Vault Sensor, <br />Model: VR 407 <br />X Plpfng Sump / Trench Sensor("), <br />Model: VR 208 <br />X Fill Sump Sensor(s). <br />Model: VR 208 <br />X Mechanical Line Leak Detector <br />Modal: FE PETRO <br />❑ Electronic Line Leak DeteOtor, <br />Model: <br />0 Tank Overfili I High -Levet Sensor, <br />Model: <br />L Others gel o ul ment tv a and modal In Sectlon E on Pape <br />Tank iD:2 UNLEADED MASTER <br />X In -Tank Gauging Probe. <br />Model, VR MAG PROS <br />X Annular Spars or vault Sensor. <br />Modes; VR 407 <br />Piping Sump /'ranch Sensor(s). <br />Model: VR 206 <br />Fill Surno Sensor(s), <br />Model: VR 206 <br />X Mechanical Llne Lsak Detector. <br />Model: FE PETRO <br />U Electronic Line Leak Detector, <br />Model; <br />C Tank Overfill I HIgh-Level Sensor, <br />Model: <br />u Other (specify equpment type and model <br />In Section E on Pace: <br />Dispenser ID; 1/2 <br />X Dispenser Containment Sensor(s). Model: VR 208 <br />D Shear Vaive(s), <br />Dispenser Containment Fioat(s) and Chain(s),_.,_ <br />Dispenser iD:314 T_ <br />X Dispenser Containment Sensor(s), Model: VR 20t <br />:1 shear valve(s). <br />Dispenear ID: 516 ' <br />X Dispenser Containment Sensor("), Model: VR 208 <br />❑ Shear Valve("). <br />Dispenser Containment Floats) and Chains <br />'If the facility contains more tanks or dlspens0M, copy this form. In <br />City: LODI gip; 966242 <br />COMact Phone No,: 530-788.2275 <br />Date ofTQsting/Servicing: 9/28/2012 <br />Tank Ib: ULEADED SLAVE <br />X In -Tank Gauging Probe_ <br />Model: VR MAG PROS <br />X Annular Space or Vrsuit Sensor. <br />X Plplrlg Sump I Trench Sensor(&). <br />Model: VR 407 <br />Model: VR <br />X Fill Sump Sensor(s). <br />20a <br />Model; VR 206 <br />X Macilanlcal Line Leak Detector. <br />Model: FE PETRO <br />11 Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill I Nigh -Level Sensor, <br />Model: <br />D Others eci o u ment type, and modal In Section E on Page ; <br />Tank ID: DIESEL <br />X In -Tank Gauging Probe, <br />Model; VR MAG PROS <br />X Annular Space or vault Sensor. <br />Model: VR 407 <br />X Piping Sump/Trench Sensor(s), <br />Model: VR 208 <br />X Ftll Sump Sensor(&). <br />Model: VR 246 <br />X Mechanical Line Leak Data=r. <br />Model: VMI LD 2000 <br />Electronic Line Leak f7etector. <br />Model: <br />❑ Tank Overfill I High -Leval Sensor. <br />Model: <br />r; Other (seacILSquIpmentlype and model In Section E on Page, <br />Dispenser iD: 7(8 <br />X Dispenser Containment Sonsor(s). <br />Model: VR 208 <br />L'� Shear Vaive(e). <br />Dis enser Containment Floatand <br />s <br />Chains . <br />Dlsponser ID: 8/j0 <br />X Dispenser Containment Sensor(s), <br />Model: VR 208 <br />Q Shear Vaive(s). <br />Dls enser Containment Floats and <br />Chain & . <br />Dispenser ID: <br />X Dispenser Containment Sensor(s). <br />Modal: VR 08 <br />❑ Shear ValvG(s), <br />D Dis enser Containment Floats and Chain(s). <br />Tilton for every tank and dispenser at the facility, <br />C. Certification - I certify that the equipment Identified In this document was InspectOd/serviced In accordance with the manufacturers' <br />guidellnos. Attached to this Certification is information (a.0. manufacturers' checklists) necessary to verify that this Information Is correct <br />and a Plot Plan ehowing the layout of monitoring equipment, For any equipme t capblo of generating such reports, I have alto attached a <br />copy of the report; (chock&u thatapply). ❑ System tet -up E Alarrn hi r9 ort <br />Technician Name (print): JAMES PAY Signature: J <br />Certification No.; A2274Q License. No,: 955 <br />Testing Company Name: MID VALLEY CONSULTING Phone No.:(53 748-9892 <br />Testing Company Address: 1097 BRONCO DRIVE, PLUMAS LAKE, CA a6061 Data Of TestInWServicing__ 9IPal2012 <br />Monitoring System Certificatlon Page 1 of 4 12/oy <br />1 2/21/07 <br />