Laserfiche WebLink
OPQUIN.� <br />q�%FoR/ <br />February 22, 2013 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue <br />Pat Mulhall <br />Petroleum Services Inc. <br />1721 2nd St. Suite 201 <br />Sacramento, CA 95811 <br />Stockton, California 95205-6232 <br />Website: www.sjgov.org/ehd <br />Phone: (209) 468-3420 <br />Fax: (209) 464-0138 <br />Re: Flag City Chevron 6421 Capitol Ave. Lodi, CA 95242 <br />DIRECTOR <br />Donna Heran, REHS <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, RENS, RDI <br />Kasey Foley, REHS <br />Linda Turkatte, REHS <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of <br />the permit application for testing the 87 leak detector (main ust), 87 spill container (main ust), <br />and 91 spill container, diesel annular sensor, and L3 87 annular sensor (siphon ust) and to <br />repair any failed components from these tests on the underground storage tank (UST) system at <br />the above noted address. The permit has been approved with the following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control <br />District for any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval <br />prior to commencing work. All new addenda supersede the previous ones. <br />3. Contact Aris Cacapit at (209) 468-3453 to arrange the following inspection appointments <br />(a 48-hour notice is required for inspection appointments). Please be aware that <br />inspections for emergency work must be scheduled within five days of permit approval. <br />a. Sensor functionality: Functionality of the monitoring system must be verified to <br />ensure that monitoring has been restored to meet the requirements of Title 23 <br />California Code of Regulations and the Health & Safety Code. <br />b. Leak detector test: Leak detector must be tested to confirm that the device can <br />detect a leak of 3 gallons per hour at 10 psi. <br />c. Spill bucket test: Verify minimum 5 -gallon capacity and pass a one hour hydrostatic <br />test (or equivalent). Proper drainage must also be verified. <br />Please be aware that the facility cannot receive fuel in the 87 tanks prior to the <br />EHD inspection and approval. <br />4. Qualified service technicians must possess or work under the direct and personal <br />supervision of an individual physically present at the work site who possesses all of the <br />following: <br />a. One of several permissible valid, current contractor's licenses issued by the <br />Contractors State License Board (may be issued to the installation company), or a <br />Tank Tester's license issued to the individual by the State Water Board, and <br />