My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO_2014 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 2:30:29 PM
Creation date
4/10/2019 4:46:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2018
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br />Appendix VI CCT 14 2016 <br />MONITORING SYSTEM CERTIFICATION ENVIROWEW; <br />For Use By All Jurisdictions Within the State of California ppq���T, �-HEALTH <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofPF�eg'lS W&WOES <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information V <br />Facility Name: FLAG CITY CHEVRON Bldg. No.: <br />Site Address: 6421 CAPITAL City: LODI Zip: 95242 <br />Facility Contact Person: KUI <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 <br />Contact Phone No.: (209) 334-0975 <br />Date of Testing/Servicing: 9/26/2016 <br />B. Inventory of Equipment Tested/Certified <br />Check the annronriate boxes to indicate snecifir. PnuinmPnt insnPrtPd/servir.Pd- <br />TankID: 87 <br />Tank ID: 91 <br />® In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />® In -Tank Gauging Probe. <br />Model: MAG 1 <br />® Annuiar Space or Vault Sensor. <br />Model: <br />409 <br />® Annular Space or Vault Sensor. <br />Model: 409 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />® Fill Sump Sensor(s). <br />Model: 208 <br />® Mechanical Line Leak Detector. <br />Model: <br />PE PETRO <br />® Mechanical Line Leak Detector. <br />Model: PETRO <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />DIE <br />Tank ID: 87SYPON <br />® In -Tank Gauging Probe. <br />Model: MAG 1 <br />7ank <br />k Gauging Probe. Model: MAG 1 <br />r Space or Vault Sensor. <br />Model: <br />409 <br />® Annular Space or Vault Sensor. <br />Model: 409 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />® Fill Sump Sensor(s). <br />Model: 208 <br />® Mechanical Line Leak Detector. <br />Model: <br />LD 2000 <br />® Mechanical Line Leak Detector. <br />Model: PE PETRO <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 9-10 <br />DispenserlD: 11-12 <br />® Dispenser Containment <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />-It the tacility contains more tanks or dispensers, copy this tocol. Include information Tor every tank and dispenser at the tacility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that applv): ® System set-up El Alarm history report <br />Technician Name (print): FELIX RAMIREZ <br />Signature: <br />Certification No.: 834976 License No: 5273934 -UT 08-1740 OTTL <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 4162 nd STREET GALT, CA 95632 Date of Testing/Servicing: 09-26-16 <br />Monitoring System Certification <br />Page 1 of 4 <br />2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.