My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO_2014 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 2:30:29 PM
Creation date
4/10/2019 4:46:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2018
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI *RECEIVED <br /> MONITORING SYSTEM CERTIFICATION OCT 1 1 2016 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or repor�rr�}yS)t, prp��rpd,) ^L HEALTH <br /> monitoring system control panel by the technician who performs the work.A copy of this form must be p 1 <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 dJCda ENT <br /> A. General Information <br /> Facility Name: FLAG CITY CHEVRON Bldg.No.: <br /> Site Address: 6421 CAPITAL City: LODI Zip: 95242 <br /> Facility Contact Person: KUI Contact Phone No.: (209)334-0975 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 9/26/2016 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> TanklD: 87 TanklD: 91 <br /> N In-Tank Gauging Probe. Model MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> N Annular Space or Vault Sensor. Model. 409 ® Annular Space or Vault Sensor. Model: 409 <br /> N Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> N Fill Sump Sensor(s). Model: 208 ® Fill Sump Sensor(s). Model: 208 <br /> N Mechanical Line Leak Detector. Model: PE PETRO ® Mechanical Line Leak Detector. Model: PETRO <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIE Tank ID: 87 SYPON <br /> N In-Tank Gauging Probe. Model: MAG 1 N In-Tank Gauging Probe. Model: MAG 1 <br /> N Annular Space or Vault Sensor. Model: 409 N Annular Space or Vault Sensor. Model: 409 <br /> N Piping Sump/Trench Sensor(s). Model: 208 N Piping Sump/Trench Sensor(s). Model: 208 <br /> N Fill Sump Sensor(s). Model: 208 N Fill Sump Sensor(s). Model: 208 <br /> N Mechanical Line Leak Detector. Model: LD 2000 N Mechanical Line Leak Detector. Model: PE PETRO <br /> ❑ Electronic Line Leak Detector. Model: N Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> N Dispenser Containment Sensor(s). Model: 208 N Dispenser Containment Sensor(s). Model: 208 <br /> N Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> N Dispenser Containment Sensor(s). Model: 208 N Dispenser Containment Sensor(s). Model: 208 <br /> N Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> DispenserlD: 9-10 DispenserlD: 11-12 <br /> N Dispenser Containment <br /> N Dispenser Containment Sensor(s). Model: 208 Sensor(s). Model: 208 <br /> N Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): N System set-up N Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: <br /> Certification No.: 834976 License No: 5273934-UT 08-1740 OTTL <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2nd STREET GALT,CA 95632 Date of Testing/Servicing: 09-26-16 <br /> Monitoring System Certification Page 1 of 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.