3.0 RESULTS OF THE INVESTIGATION <br /> 31 Geology and Hydrogeology <br /> Soils observed during the drilling of the three monitoring well borings to a maximum depth of 87 <br /> feet bgs consisted mostly of massive intervals of clay, silt and fine sand mixtures interrupted by <br /> thin (i e, less than five feet thick) intervals of poorly-graded fine sand Laterally continuous sand <br /> sequences were observed at approximately 15 feet bgs and at 75 to 80 feet bgs Other sand <br /> intervals were observed as laterally discontinuous across the site Detailed sod descriptions are <br /> included on the monitoring well logs (Appendix C) <br /> During drilling on August 31 and September 1, 2000, saturated soil and groundwater were first <br /> encountered between 79 5 and 80 1 feet bgs On September 7, 2000, the static depth to the <br /> groundwater table, as measured in the three groundwater monitoring wells, ranged from 77 40 <br /> feet bgs in MWA to 78 23 feet bgs in MW-3 As such, groundwater does not appear to present <br /> under significant confining conditions Groundwater recharge was observed to be moderately <br /> strong <br /> The groundwater surface elevation ranged from a high of 22 64 feet (arbitrary datum) at MW-2 to <br /> a low of 22 42 feet (arbitrary datum) at MWA The resulting groundwater surface appears as a <br /> regular plane dipping to the north-northeast at a gradient of approximately 0 0037 foot/foot A <br /> groundwater surface contour map is included as Figure 4 The well construction details, wellhead <br /> elevations and groundwater monitoring data are summarized in Table 3 <br /> 32 Analytical Results <br /> The 12 sod samples collected during the investigation did not contain detectable concentrations of <br /> any of the gasoline constituent compounds analyzed These sod sample results are summarized <br /> in Table 1 and the laboratory reports are included in Appendix D <br /> The groundwater samples collected from all three of the groundwater monitoring wells and the on- <br /> site domestic water well did not contain detectable concentrations of any of the gasoline <br /> constituent compounds analyzed These groundwater sample results are summarized in Table 2 <br /> and the laboratory reports are also included in Appendix D <br /> 12 <br />