Laserfiche WebLink
-Measures fuel m' ventory <br /> accurately and automatically... <br /> tests tanks on demand! <br /> The TLS-250 Tank Level Sensor continuously its liquid crystal display or provide a printout(on <br /> monitors fuel stored in underground tanks and pro- models equipped with the integral printer). In addi- , <br /> vides inventory information on demand or automati- tion, inventory information can be transmitted via the I <br /> cally at report times programmed by you. system's RS-232 communications port to a point-of- <br /> Permanently mounted tank probes use capaci- sale terminal or computer. <br /> tance technology to accurately measure the height At any time or at programmed times estab- <br /> of fuel, height of water and temperature of fuel in lished by you and when no fueling is taking place, <br /> each tank and transmit this information to the the TLS-250 may be placed in its Leak Detect mode. <br /> system monitor. One monitor can handle up to It is capable of sensing losses as smal I as 0.2 gal- <br /> eight tanks. Ions per hour and will provide a PASS/FAIL/WVALID <br /> The TLS-250 monitor calculates fuel volume report at the end of the test period. <br /> and ullage and can show all inventory information on <br /> Loaded with features to improve management control <br /> ► On-Demand Inventory Report ► Programmable Alarm Configuration <br /> ■ Gallons,of Fuel Ties Any/All Alarm Indicators to R <br /> ■ .nches of Fuel Output Relays* <br /> ■ Ullage <br /> ■ Inches of Water ► External Input Interface Integrates 0 <br /> ■ Temperature of Fuel Signals from Other Monitoring <br /> Devices* <br /> ► ,automatic Inventory Increase Report <br /> ► Programmable Times for Automatic <br /> ► Automatic and On-Demand Leak Tests Reporting <br /> ■ Single or all tanks .F <br /> ► One System Monitors Up To Eight - <br /> ► Automatic Leak Test Validity Checks* Tanks <br /> ► Final Leak Rates with PASS, FAIL and ► Handles Manifolded Tanks <br /> INVALID Leak Test Result Indicators* <br /> ► Two-Wire, Factory-Calibrated ' <br /> ► Overfill Alarm Feature ' "Smart" Probes <br /> ► Programmable Alarm Limits and ► RS-232 Communications Interface <br /> Indicators Identify: <br /> ■ Theft - ■ High Water P. On-Site and Remote <br /> ■ Leak Losses ■ Overfills Self-Diagnostics <br /> ■ Low Inventory -1 <br /> ► Available With or Without Integral :.: <br /> ► Two Alarm Relays Can Trigger Printer <br /> Alarm/Security Devices <br /> ► Emergency Generator Version (see <br /> ► Simple to Order--Just Specify back page)* <br /> Tank Diameters *New' <br /> muss!=�.,�� �trr+aaP'+'� �rer�3snn���,-xaY.m� taa�c�a�v-•:x-r �-„ ,�rx�ren,.�.t' x '� ,ec �•�r� «-t ,. <br />