2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 1994 - 2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2022 4:45:56 PM
Creation date
4/26/2019 2:27:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994 - 2000
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> �Tanlv�ology <br /> TEST DATE:09/30/98 8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER2206081 <br /> CLIENT:ULTRAMAR INC AUSTIN,TEXAS 78757(512)451-6334 SITE:ULTRAMAR #696 <br /> TANK INFORMATION <br /> Tank ID: i Tank manifolded: NO Bottom to top fill in inches: 149.0 <br /> Product: PREMIUM Vent manifolded: No Bottom to grade in inches: 153.0 <br /> Capacity in gallons: 9,728 Vapor recovery manifolded: YES Fill pipe length in inches: 57.0 <br /> Diameter in inches: 92.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 342 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: BALANCE <br /> CP installed on: <br /> COMMENTS <br /> TANK TEST RESULTS Test Method:VacuTect LEAK DETECTOR TEST RESULTS ?Test method: <br /> Start(in) End(in) <br /> Dipped Water Level: New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: RED JACKET <br /> Ingress Detected: Water Bubble Ullage Model: X.L.P. <br /> Test time: S/N: 207947494 <br /> Inclinometer reading: Open time in sec: 1.00 <br /> Holding psi: 15 <br /> VacuTect Test Type: NOT Resiliancy cc: 910 NOT <br /> VdCUT2Ct Probe Entry Point: TESTED TESTED <br /> Test leak rate ml/m: 189.o <br /> Pressure Set Point: Metering psi: 10 <br /> Tank water level in inches: Calib. leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> LINETEST RESULTS Test type: TLD-1 <br /> LINE A, B C D <br /> Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length (ft): 140.0 <br /> Test psi: 50 <br /> Bleedback cc: 270 <br /> Test time (min): 30 NOT NOT NOT <br /> Start time: 20:57 TESTED TESTED TESTED <br /> End time: 21:19 <br /> Final gph: 0.010 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 10/15/1998 16:09 <br />