Laserfiche WebLink
TYPICAL <br /> UNDERGROUN <br /> k. <br /> NSTAL ON F0 <br /> SERVICE S ION <br /> Easy, Economical with special profile double-lead The system-matching <br /> Installation threads. Combined with adhesive at adhesive is applied to all <br /> Lightweight RED THREAD II pipe is time of assembly,the T.A.B.Joint is also bonding surfaces, and the fitting <br /> fast and easy to install. The standard halves are then joined and bonded. <br /> available in 15 and 30 ft.random lengths. joining procedure for field-made Proper assembly and bonding <br /> The easy-to-use T. Joint, epoxy bonds is achieved by procedures are detailed in Smith Fiber- <br /> standard on UL/ULCC RED THREAD II _ the mechanical locking glass Products Manual No. B2160. Or, <br /> Fiber- <br /> pipe, promotes fast positive action of matching bell and contact your local Smith Fiberglass <br /> makeup and prevents spigot taper angles. Products distributor for a video <br /> "backout" problems presentation. <br /> during cure time. Fittings compatible with the <br /> The combina- product piping are also listed by <br /> tion of light Underwriters Laboratories for use in <br /> weight, underground handling of petroleum <br /> products. <br /> joining <br /> and Hd When connecting containment pipe <br /> biand fittings,plain ends of the containment <br /> easy oining pipe are machined or thoroughly sanded <br /> assures econo- <br /> mical installation. <br /> to accept the two-piece U L/ULC Listed <br /> containment fitting. Containment pipe <br /> Joining System must be positioned over the product "_`_ <br /> The exclusive T.A.B. (Threaded and piping prior to assembly and bondingof <br /> Bonded) Joint is factory installed. It is the product pipe system. <br /> the standard joining system for UL/ULC Upon completion of a successful prod <br /> Special two-piece containment fittings allow <br /> Listed RED THREAD II pipe.Spigot and uct pipe test procedure, the secondary the product piping to be tested before the <br /> bonded-on coupling ends are threaded containment fittings may be installed. system is sealed. <br /> GENERAL SPECIFICATIONS AND RATINGS(') <br /> External Pressure <br /> Nominal Nominal Nominal Nominal Nominal Mill Test Max.Rating psig/MPa at Random <br /> Pipe Size O.D. I.D. Wall Thickness Weight Pressure-Temp. Pressure Lengths <br /> in. in./mm in./mm In./mm lbs.-K./kg-m Max.Rating psig 75°F/21°C 150°F/66°C R./m <br /> 2.375 2.235 0.070 0.4 250 psig @ 150° F 1000 112 106 15 30 <br /> 2 <br /> 3.500 3.360 0.070 0.6 175 psig @ 150°F 700 29 23 15 30 <br /> 3 <br /> 4.530 4.360 0.085 1.0 F125 psig @ 150°F 500 34 30 15 30 <br /> 4 <br /> (1)All values except pressure-temperature maximum rating are nominal values.Tolerances or maximum/minimum limits can be obtained trom Smith Fiberglass Products Inc. 'r <br /> 4 <br />