INSTALL 1994 PIPING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
INSTALL 1994 PIPING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2022 4:58:51 PM
Creation date
4/26/2019 2:34:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1994 PIPING
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Spedcafionsoontinued <br /> Displays. Motors(self-contained models). • <br /> The Advantage series uses highly reliable,highly MPD Three-Grade: 1-1/2 HP,230V AC.60 cycle, <br /> readable LCD displays. Readable even without single phase,explosion-proof motor and 3/4 HP, <br /> backlighting. 230V AC 60 cycle,single phase,explosion-proof motor. <br /> Quad: 1-1/2 HP,230V AC,60 cycle,single phase, <br /> Main Display. explosion-proof motor. Dual: 3/4 HP,230V AC, <br /> Money: 1"high,six digits. 60 cycle,single phase,explosion-proof motor. <br /> Volume: 1"high,six digits,gallons or liters. International versions are available. <br /> Price-per-unit: X high,four digits. <br /> Puiser. <br /> PPU Module. Patented,solid state'fail safe'pulser is driven directly <br /> Price-per-unit: .5"high,four digits. off the meter. Generates 1,000 pulses per gallon. <br /> Graphic Panels. Vapor Recovery. <br /> Backscreened polycarbonate panels with adhesive. Ask All models in The Advantage series are built vapor <br /> your Gilbarco distributor for information on customized ready unless full vapor recovery is specified. <br /> graphics for The Advantage series. <br /> Battery Back-Up. <br /> Lower Door. Battery provides power to the electronics(including <br /> Locking lower door. Available painted or stainless displays)for fifteen minutes after a power failure <br /> steel. Ask your Gilbarco distributor for more occurs. <br /> information. <br /> Hoses And Nozzles. <br /> Mechanical Totalizers. The Advantage series uses the standard Gilbarco <br /> 99.999.99 gallon non-resectable mechanical totalizers selection of hoses and nozzles. Hoses and nozzles are <br /> display the volume dispensed at that dispenser for customer-specified items. <br /> each meter. <br /> Approvals. <br /> Filters. UL and CSA Listed. All conform with NIST Handbook <br /> One standard or water alert Gilbarco 10-micron high 44. NTEP Cert.No.90-115. <br /> capacity spin-on filter per underground product. <br /> Load Specifications <br /> Two-Stage Valves. Lights: 1.0 AMP @ 120V AC <br /> Dual now.pilot-operated diaphragm valves. Solenoid Valves: 1.0 AMP @ 120V AC <br /> Submerged Turbine Pump(STP): 0.3 AMP Max. <br /> Blend Valves. @ 120V AC <br /> Highly accurate Proportional Flow Control-valves Electronics Module: 2.5 AMP @ 120V AC <br /> achieve the desired blend ratio through precise CRIND-: 1.0 AMP @ 120V AC <br /> positioning and a continuous closed-loop electronic <br /> feedback system. These innovative valves also perform Operating Environment: <br /> as combination"fail safe'/pressure relief valves. Relative Humidity: 5%to 95%non-condensing <br /> Minimum Ambient Temperature: 13°F(-30°C) <br /> Meters Maximum Ambient Temperature: 1040F(40°C) <br /> Highly accurate four-piston positive displacement <br /> meters. Can be calibrated to increments as small as Performance Requirements: <br /> 1/3 cubic inch in five gallons. Calibration wheel is Minimum Dispenser Delivery Rate: 11 GPM @ 26 PSI <br /> easily accessed. inlet pressure(with unleaded nozzle) <br /> Meter Accuracy: ± .25%from 1.5 to 15 GPM <br /> Power Requirements. <br /> 120V AC(+10%,-15%).50/60 Hz. International i uel Limitations: <br /> models are available. Maximum Ethanol Content: 10% <br /> Maximum Methanol Content: 5% <br /> Ilydraulic Manifold- <br /> AdImxlucts an:manufactunxl or <br /> Ad underoncormoreofthefollouing New hydraulic manifold design incorporates meters. <br /> UnKW states pateats: 3.814.934: valves,filter,and inlet casting into a single module. Product specifications are subject to change. <br /> 4:166.504:4.687.03:1:4.728.788: <br /> 4.799.949: 4.879.953: 4.890,210; <br /> 4.913.813: 4018.251: 4.93933 <br /> 4.986.445: 5.013.434: 5.029.1W: <br /> D.316,471. Additional Uniuxl S-wLes <br /> and foreign pau!n(s lending. <br />
The URL can be used to link to this page
Your browser does not support the video tag.