Laserfiche WebLink
'WnY ONITORING SYSTEM CERTIFICATION <br /> Foy ise By All Jurisdictions Within the State of Californi6 <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3 Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: USA#03696 City: LODI CA Zip:95242 <br /> Site Address: 2448 W KETTLEMAN LN Contact Phone NO:369-3124 <br /> @ LOWER SACRAMENTO RD 09/12/2003 <br /> Date of Testing/Service: <br /> Facility Contact Person: MGR-BETH <br /> Make/Model of Monitoring System: GILBARCO EMC Work Order Number: 2228417 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1 Tank ID: 2 <br /> 71 In-Tank Gauging Probe. Model: 2650960200 ZI In-Tank Gauging Probe. Model: 2650960200 <br /> X Annular Space or Vault Sensor. Model: 794390407 Annular Space or Vault Sensor. Model: 794390407 <br /> X Piping Sump/Trench Sensor(s). Model: 2592000000 Piping Sumpffrench Sensor(s). Model: 2592000000 <br /> X Fill Sump Sensor(s). Model: 2592000000 Fill Sump Sensor(s). Model: 2592000000 <br /> Mechanical Line Leak Detector. Model FX1V FX1V' <br /> Mechanical Line Leak Detector. Mode: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: 61 SO X Tank Overfill/High-Level Sensor. Moce! 61 SO <br /> Omer(specify equipment type and modei in Section E on page 2). Other(speciry equipment type and model in Section E on page 2). <br /> TanklD: 3 TanklD: <br /> X In-Tank Gauging Probe. Model: 2650960200 7 In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 794390407 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model: 2592000000 Piping Sump/Trench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model: 2592000000 7Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: FX1 V 7 Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: 7 Electronic Line Leak Detector. Model: <br /> X Tank Overfill/High-Level Sensor. Model: 61 SO Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). 7 Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 112 Dispenser ID: 3/4 <br /> 71 Dispenser Containment Sensor(s) Mode:: 7 Dispenser Containment Sensor(s) Model: <br /> X❑Shear Valve(s). X Shear Valves) <br /> ❑X Dispenser Containment Float(s)and Chain(s) X Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> 7 Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> XD Shear Valve(s). Shear Valve(s). <br /> X Dispenser Containment Float(s)and Chain(s). 7Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). 7Shear Valve(s). <br /> Dispenser Containment Fioat(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up report; ❑ Alarm history report XO <br /> PRINTED NAME:JEFF CONGER SIGNATURE: <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 03/01 <br />