COMPLIANCE INFO 2001 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2001 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 9:19:58 AM
Creation date
4/26/2019 4:27:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2006
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ask Ask, <br /> NW <br /> PRODUCT PIPING SUMP TESTING <br /> Test Method By: Manufacturer • Industry Standard Professional Engr o Other(see below) <br /> Test Method Uses: Pressure vacuum • Hydrostatic o Other(see below) <br /> Measuring Equipment Used: INCON TS-STS (Electronic Sump Test System) <br /> Description Tank#1 Tank#2 Tank#3 <br /> Tank product Gasoline 87 Gasoline 89 Gasoline 91 <br /> Sump material FRP FRP FRP <br /> Sump diameter (inches) 42 42 42 <br /> Sump depth (inches) 62 62 62 <br /> Height from tank top to highest 16 19 24 <br /> piping penetration (inches) <br /> Height from tank top to lowest 16 16 15 <br /> electrical penetration (inches) <br /> Method of sump attachment to tank Tank Collar Tank Collar Tank Collar <br /> Condition of sump prior to testing Dry <br /> Portion of sump tested Entier <br /> Is system programmed for fail-safe operation? Unknown <br /> Was fail-safe verified to be operational? N/A <br /> Was sensor removed for testing? Yes <br /> Was sensor properly replaced after testing? Yes <br /> Depth of water level from tank top (inches) 19 <br /> Wait time for water level to stabilize (hr:min) 0:10 <br /> Test start time 2:00 PM <br /> Initial Probe Reading 5.6705 <br /> Test end time 2:15 PM <br /> Final Probe Reading 5.6711 <br /> Test duration (hr:min) 0:15 <br /> Change in water level (±0.0000 inches) 0.0006 <br /> Pass/Fail threshold (±0.0020 inches/;Hr.) 0.0020 <br /> TEST RESULT PASS <br /> Comments: <br /> This was a re-test of the 87 STP sump after repairs. <br /> © 2006 Walton Engineering,Inc. <br />