MINIMUM VERIFICATION LABORATORY ANALYSIS <br /> TANKEN <br /> TANK TPH-G TPH-D BTX&E CL HC TOTAL MTBE AA ES EN <br /> °W''L PCB <br /> # CONTENTS 8015 8015 8020 8010 LEAD 8020 (MTBE. <br /> 8260 8260 8260 8240 7420 8260 TBA.DIPF., ICAP/ 8270AES or 8080 <br /> 8260 7421 TME) AA <br /> X260 <br /> LEADED GAS X X X X <br /> UNL CTAS X X X <br /> DIESEL X X <br /> KEROSENE X X X <br /> UNK FUEL X X X X X <br /> PROD.OIL X X X <br /> CHLOR. <br /> SOLVENTS X X X <br /> NONCHLOR <br /> SOLVENTS X X X <br /> W ASTF\ <br /> USED OIL X X X X <br /> X X X <br /> All analysis methods are the designated EPA methods described in EPA SW 846,Third Edition. Those methods not found in SW 846 are <br /> specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix D (B),Table 3-5 on page A20 for minimum detection <br /> limits for motor vehicle fuel (gasoline and diesel). Refer to "Tri-Regional Board Staff Recommendations for Initial Evaluation and <br /> Investigation of UST's" for the waste and motor oil minimum detection limits. Detection Limits that remain below the MCI-STLC or <br /> Allowable Limit of the contaminant in question will be accepted,however laboratory shall utilize the most conservative method. <br /> TPH-G Total Petroleum Hydrocarbon,Gasoline,GC/BFID 030R)8015mod orEGC/MSM260 LOGY. <br /> TPH-D Total Petroleum Hydrocarbon,Diesel,GC/FID(3550),8015 mod or GC/MS 8260 <br /> BTX&EBenzene,"Foluene,Xylene&Ethyl Benzene,GC/PED 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC/HSD 8010,GC/MS 8240 or 8260 <br /> TOTAL LEAD 1 otal lead,AA 7420, AA 7421 or ICP-AES 6010 <br /> OXYGENATES VFFBF.,ETBE,"FAME,D1 PE,&TBA GC/MS 8260(For MTBE screen only you may use 8020) <br /> METALS[CAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000, Metals: <br /> Cadmium,Chromium III and VI,Lead,Linc and Nickel. <br /> PCB Polychlorinated Biphenyls,GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid talse positive defection of benzene,benzene-free solvents are to he used_ Fused capillary columns are preferred to hacked coltunns.a <br /> packed column may be used as a"first cut"with"dirty"samples or once the hydroa:arbons have been characterized and proper QA/QC is followed For <br /> drinking water sources,EiPA recommends that the 500 series for volatile organic should he used in preference to the 600 series because the detection <br /> limits are lower and the QA/QC is better. Samples exhibiting any level of heavv metal contamination may require further analysis PHS-EHD <br /> recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 05/09/00) <br /> 5 <br />