Laserfiche WebLink
T 4 <br /> San Joaquin County DIRECTOR <br /> Donna Heran,REHS <br /> .� Environmental Health Department <br /> ASSISTANT DIRECTOR <br /> Laurie Cotulla, REHS <br /> 2� 600 East Main Street <br /> W T X Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> �. Carl Borgman, REHS <br /> • Mike Huggins,REHS, RDI <br /> cq•. �, .�;:P Website: www.sjgov.org/ehd Margaret Lagorio,REHS <br /> %F 6 R Phone: (209)468-3420 Robert McClellon,REHS <br /> r Fax: (209) 464-0138 ,teff Carruesco, REHS,RDI <br /> Kasey Foley,REHS <br /> June 12, 2008 <br /> Marty Weithman Sent by: Fax and Mail <br /> Service Station Systems <br /> 680 Quinn Ave <br /> San Jose, CA 95112 <br /> RE: USA Gas, 2448 W Kettleman Lane, Lodi, CA (SR0054513) <br /> The San Joaquin County Environmental Health Department(EHD)has completed the <br /> review of the application for permit to install a VMI LD 2000 mechanical line leak <br /> detector(MLLD) on the 91 product line at the above noted address. The MLLD was <br /> installed on June 28, 2008 and passed the three gallon per hour at ten psi functionality <br /> test. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution <br /> Control District for any applicable permits and requirements. <br /> 2. A "Certification of Installation/Modification" shall be submitted by the <br /> owner or the owners' agent [pursuant to (CCR) 2635(d)] before this repair <br /> will be considered complete by the EHD. <br /> 3. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all <br /> of the following: <br /> a. One of several permissible valid, current contractor's licenses issued by <br /> the Contractors State License Board (may be issued to the installation <br /> company), and <br /> b. A valid, current California UST Service Technician certificate issued by <br /> the International Code Council (ICC), and <br /> c. A valid, current certificate of training from the manufacturer(s) of the <br /> component(s) being tested,repaired, or serviced, and <br /> d. Each person installing or testing any component must hold a certificate of <br /> training from the manufacturer of that component. <br /> 4. Permit expires 180 days from date of approval. Note: If an extension to the <br /> expiration date is required, a written request must be submitted to this office prior <br /> to the expiration date. <br /> Page 1 of 2 <br />