JUN-26-2009 08:25 Service Station Systems 408 938 8888 P.04 <br /> Monitoring System Certification-Pay 13 <br /> Site Address: 2448 W. Kettleman Ln. @ Lower Sacramento Date of Testing/Servicing: 5127109 <br /> D. Results of Testing/Servicing <br /> Software Version Installed- 122.00 <br /> Complete the follo ing checklist: <br /> CE Yes ❑ No' Is the audible alarm operational.? <br /> 1H Yes O No* Is the visual alarm operational? <br /> CE Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> U Yes 0 No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation'? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g. modem) <br /> 3 N/A operational'? <br /> M Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) Ct Sump/Trench Sensors; 0 Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? U Yes ❑ No <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e.no <br /> M N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating pro rly? If so, at what percent of tank capacity does the alarm trigger? 0 % <br /> M Yes' ❑ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E, below. <br /> ❑ Yes* la No Was Iiquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product;0 Water. if yes,describe causes in Section E, below. <br /> fH Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings? Attach set-up re orts, i a licable. <br /> la Yes O No* Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these dericiencies were or will be corrected. <br /> E. Comments: Replaced T2 89 Mechanical Leak Detector <br /> Had difficulties removing Annular Space Sensors. Additional tech came to the site and was <br /> able to remove and reinstall them. Tested okay. Alarm history tape for sensors attached. <br />