Laserfiche WebLink
nom- o� <br /> IED PROGRAM CONSOLIDATED FOW <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE i ��Lly�Q3 <br /> (two pages per tank) <br /> Page of <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 130 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: <br /> USA GASOLINE#3696 3 3��S <br /> LOCATION WITHIN SITE(optional) <br /> L TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434 <br /> 15 MO OWENS CORNING If-Yes",complete one page for each compartment. <br /> DATE INSTALLED O) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 1989 10,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ®1. MOTOR VEHICLE FUEL ®1 a. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifmarked complete Petroleum Type) ❑ I b. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑ 1 c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (ftom Hazardous Materials inventory page) 441 CAS#(from Hazardous Materials inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Inchides Used oil) <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK 0 1. SINGLE WALL 0 3. SINGLE WALL WITH U 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank 0 1. BARE STEEL ❑3.FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/1001/b METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-..defy tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ®4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/1001%METHANOL [199.OTHER <br /> REINFORCED PLASTIC(FRP) [110.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED 3.EPDXY LINING 0 5.GLASS LINING 13 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 448 <br /> PROTECTION IF APPLICABLE PROTECTION ❑41MPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For low use may) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ®1 SPILL CONTAINMENT 2003 ❑1 ALARM ❑3 FILL TUBE SHUT OFF VALVE <br /> ®2 DROP TUBE 2003a ®2 BALL FLOAT ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1989 <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 1 TANK FILLED WITH R ERT MATERIAL? 457 <br /> gallons 0 Yes 0 No <br />