Laserfiche WebLink
ZKuAML AdftL <br /> o\ <br /> WH D PROGRAM CONSOLIDATED FO r� <br /> TANKS <br /> UNDERGROUND STORAGE TANKS- TANK PAGE <br /> (two pages per tank) <br /> Page of <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY IID: I <br /> IT <br /> USA GASOLINE#3696 3 F4,3dc7 <br /> LOCATION WITHIN SITE(optional) 431 <br /> L TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# nn 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434 <br /> XV V OWENS CORNING If"Yes",complete one page for each compartment <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 1989 10,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ®1. MOTOR VEHICLE FUEL [Ila. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> Qfmarkedcomplete Petroleum Type) ❑lb. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> [12.NON-FUEL PETROLEUM ®ic. MIDGRADE UNLEADED ❑4. GASOHOL [199.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Inchtdes Used Oil) <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK E3 I. SINGLE WALL 0 3. SINGLE WALL WITH 0 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 44 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT [199. OTHER <br /> TANK MATERIAL-primary tank ®1. BARE STEEL 0 3. FIBERGLASS/PLASTIC 5. CONCRETE ❑95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100°4 METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(I") <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC 0 5. CONCRETE ❑95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL IN 4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) [110.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED 3.EPDXY LINING 5.GLASS LINING 95.UNKNOWN 446 DATE INSTALLED 14 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 448 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ®1 SPILL CONTAINMENT 2003 ❑1 ALARM ❑3 FILL TUBE SHUT OFF VALVE <br /> ®2 DROP TUBE 2003 ®2 BALL FLOAT ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1989 <br /> IV.TANK LEAK DETECTION(A descriptio[of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check an that apply) 453 IF DOUBLE WALT,TANK OR TANK WITH BLADDER 151 <br /> (Check one item only) <br /> ❑I VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MIG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> [:13 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) [116.ANNUAL INTEGRITY TEST(0.1 GPM <br /> ❑17. DAILY VISUAL CHECK ❑17. DAILY VISUAL CHECK <br /> VIIL DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ®1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE [14.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ❑2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑5.TRENCH LINER/MONITORING <br /> 1989 ❑3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑6.NONE 469 <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> IDL OWNER/OPERATOR SIGNATURE <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIGN OF OWNE RATOR DATE 470 <br /> 11/7/03 <br /> NAME OF OWNER/ PRATOR(print) I= OF OWNER/OPERATOR 472 <br /> DWARDS COMPLIANCE&TESTING OFFICER <br /> ,_SANDY <br /> Number(For local use only) 473 Permit Approved(For local use only) Permit Expiration Date(For local use only) 471 <br />