K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2022 3:44:53 PM
Creation date
4/29/2019 11:24:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,! ` • UNIFIED PROGRAM CONSOLIDATE )RM <br /> • UNDERGROUND STORAGE TANKS - TANK PAGE 2 'TANK <br /> PIPING CO <br /> NSTRUCTION Check all lltata>>1 Page of <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ®1.PRESSURE ❑2.SUCTION GRAVITY 458 ❑1.PRESSURE ❑2. SUCTION <br /> CONSIRUC770N ❑1.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460 ❑3.GRAVI'T'Y 459 <br /> ❑ I.SINGLE WALL ❑95.UNKNOWN 462 <br /> MANUFACTURER ®2.DOUBLE WALL ❑95.UNKNOWN ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER TELEFLEX 461 V MANUFACTURER <br /> 463 <br /> I.BARE STEEL ❑6.FRP COMPATIBLE w/l00% ME'111ANOI, ❑1.BARE STEE1. <br /> ❑6.FRP COMPATIDLE w/loo%ME711ANOL <br /> ❑2.STAINLESS ST'EGL ❑7.GALVANIZED STEEL I ❑Unknown ❑2. STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> ❑3.PLASTIC COMPATIBLE W/CONTENTS ❑99. Other ❑3. PLASTIC COMPATIBLE W/CONTENTS ❑8.FLEXIBLE(HDPE) ❑99. OTHER <br /> ®4.FIBERGLASS ❑8.FLEXIBLE(HDPE) ❑4. FIBERGLASS ❑9.CATHODIC PROTECTION <br /> ❑5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5 STEEL W/COATING ❑95.UNKNOWN <br /> 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 46o SINGLE.WALL PIPING <br /> PRESSURIZED PIPING(Check all that apply): <br /> 407 <br /> PRESSURIZED PIPING(Check all Orat apply): <br /> ❑ 1.ELECTRONIC LINE LEAK DE'FECT'OR 3.0 GPH TEST WITH AUTO PUMP STRUT' <br /> OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ 111. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> AUDIBLE AND VISUAL ALARMS. SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION <br /> AUDIBLE AND VISUAL ALARMS. <br /> ❑2.MONTHLY 0.2 GPH TEST ❑2. MONTHLY 0.2 GPH TEST <br /> ❑3.ANNUAL INTEGRITY TEST(0.1 GPH) ❑3.ANNUAL INTEGRITY TEST(0.1 GPI 1) <br /> ❑4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> El 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING pP y) <br /> INTEGRITY TEST(0.1 GPH) ❑5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> SAFE,SUCTION S YSTEMS(NO VALUES IN BELOW GROUNDPIPING): ❑6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> ❑7.SELF MONITORING <br /> GRAVITY FLOW SAFE SUCTION S YSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> 13 7. SELF MONITORING <br /> ❑9.BIENNIAL INTEGRITY TEST(U.I GPH) GRAVITY FLOW(Check all that apply) <br /> PP Y) <br /> ❑8. DAILY VISUAL MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING <br /> ('KIiSSl1RIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 1(1. CON'T'INUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) 10 CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) <br /> ❑a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION ❑b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> Sc NO AUTO PUMP SHUT OFF DISCONNECTION <br /> ® I I AUTOMATIC LINE LEAK DE'T'ECTOR(3.0 GPH TEST)WITH FLOW SHUT ❑c NO AUTO PUMP SHUT OFF <br /> OFF OR RESTRICTION ❑11 AUTOMATIC LEAK DETECTOR <br /> ®12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑14 CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF• EMERGENCY GENERATORS ONLY(Check all that apply) <br /> AUDIBLE AND VISUAL ALARMS ❑14. CONTINUOUS SUMP SENSOR WTT'HOUT AUTO PUMPS}(UT OFF <br /> ❑ 15 AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH OUT FLOW AUDIBLE AND VISUAL ALARMS <br /> SHUT OFF OR RESTRICTION ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑17. DAILY VISUAL CHECK ❑17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ® I.FLOAT MECHANISM THAT SHUTS 01•'F SHEAR VALVE <br /> DATE INSTALLED 468 ❑4.DAILY VISUAL CHECK <br /> ❑2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑5.TRENCH LINER/MONITORING <br /> 1994 ❑3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR <br /> DISPENSER+A()DIBLE AND VISUAL ALARMS ❑6.NONE 469 <br /> LX.OWNER/OPERA'T'OR SIGNATURE <br /> I certify flint the hrfomtation provided herein is true mut accurate to the best of my knowledge. <br /> SI TUBE OF OWNE PERATOR DATE <br /> di 3 - 1 q-0 3 470 <br /> NAME:OF OWNE OPRATOR(print) <br /> SANDYEDWARDS TITLE OFOWNER/OPERATOR ^ (� 472 <br /> o T�. j (`\U J1 a <br /> Permit Number(For heal use only) 473 Permit Approved(For local use only) �1t �� <br /> Permit Expiration Date(For Iiokal use only) 475 <br /> UPCF(1/99 revised) <br /> Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.