My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 1:14:28 PM
Creation date
4/29/2019 2:10:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. TANK ANNULAR TESTING <br />Test Method Developed By: ❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ® Vacuum ❑ Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Test plugs, venturi pump and gauges Equipment Resolution: 0.5% of span <br />Tank # 87 Tank # 91 Tank # Diesel <br />Is Tank Exempt From Testing? ❑Yes ® No []Yes ® No ❑Yes ® No <br />Tank Capacity: <br />10k <br />10k <br />10k <br />Tank Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Tank Manufacturer: <br />Owens Corning <br />Owens Corning <br />Owens Corning <br />Product Stored: <br />Gasoline <br />Gasoline <br />Diesel <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 min. <br />10 min. <br />10 min. <br />Test Start Time: <br />8:00 am <br />8:05 am <br />8:10 am <br />Initial Reading (RI): <br />7" hg <br />7" hg <br />7" hg <br />Test End Time: <br />9:00 am <br />9:05 am <br />9:10 am <br />Final Reading (RF): <br />7" hg <br />7" hg <br />7" hg <br />Test Duration: <br />1 hour <br />1 hour <br />1 hour <br />Change in Reading (RF -RI): <br />None <br />None <br />None <br />Pass/Fail Threshold or Criteria: <br />No detectable loss <br />No detectable loss <br />No detectable loss <br />Test Result: <br />© Pass ❑ Fail <br />[R] Pass ❑ Fail <br />® Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes ® No ❑ NA <br />❑ Yes ® No ❑ NA <br />❑ Yes ® No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑Yes ❑ No ® NA <br />❑Yes ❑ No ® NA <br />[]Yes ❑ No ® NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />F EB n 3 2017 <br />Eiv vfIFIv"MENTAL HEALTH <br />nEpABTMENT <br />
The URL can be used to link to this page
Your browser does not support the video tag.