Laserfiche WebLink
�I <br />G1tlF Pn N,♦ <br />Water Boards <br />State Water ReSOUrces Control Board <br />January 23, 2013 <br />Mr. Don Mukai <br />S. Bravo Systems, Inc. <br />2929 Vail Avenue <br />Commerce, CA 90040 <br />Dear Mr. Mukai: <br />1't t ,i, G. BRUWR JR. <br />\� PA4'THj1W FlO13R1QUj_— <br />',T(tIR\ FGP <br />w'a�PivlwFNln- R'Ml(!'1 ��N) <br />NOV 2 4 2014 <br />ENVIRONMENTAL HEALTH <br />DEPARTMENT <br />REVISED APPROVAL OF THE DISPENSER CONVERSION FRAME, MODEL CONV- <br />B2000/CONV-B2000-OPP AS AN UNDER -DISPENSER SPILL CONTAINMENT OR <br />CONTROL SYSTEM TO INCLUDE PROVISIONS FOR THE CONY RETROFIT PLATE <br />KIT INSTALLATION <br />This letter is in response to your application for approval of the revised S. Bravo <br />Systems, Inc. (Bravo) Dispenser Conversion Frame, model CONV-82000/CONV- <br />B2000-OPP (CONV-B2000) including the CONV Retrofit Plate Kit. This revised <br />approval letter of the Bravo Dispenser Conversion Frame CONY -132000 including the <br />CONV Retrofit Plate Kit supersedes the State Water Resources Control Board's (State <br />Water Board) approval letter dated April 8, 2008. <br />Description of the CONY -132000 <br />The CONV-132000 is a conversion frame designed to allow larger dispensers to be <br />installed above smaller existing under -dispenser containment (UDC). When piping <br />within the dispenser falls outside the footprint of the UDC, the CONV-B2000 is designed <br />to direct any leaking product into the UDC where it will be contained and detected, as <br />required by California regulations'. <br />The CONV-82000 is fabricated of galvannealed and epoxy powder coated 12 gauge <br />(0.093" thickness) steel. It is designed to prevent interference of the UDC water splash <br />guard, and includes a water splash guard to prevent water intrusion. The CONY -82000 <br />provides angles to drain releases back into existing UDC using a weir system of <br />drainage. Enclosure 1 shows a typical drawing of the CONY -132000. Exact dimensions <br />are determined when an owner or operator sends UDC and dispenser information to <br />For a detailed explanation of the requirements for dispenser piping refer to the State Water Board's <br />December 21, 2007 letter "Clarification of Existing Regulations for Under -Dispenser Containment " <br />(.HAGLVS R 1-10PFIN, ChAj,*AAfj I Tocwt iiOW!44t , EXECUTIVF OIMOTOF, <br />1 � ..- aq .—fr (;A ;1!AI•{ I kkolinq A lmr5sv P.Cr Rn. &)i 5nrrvrwilr, CA 953}$ -11;.ri I *v w *Ve wdf"5. rte ._ <br />a ■tt•rLc, PAwl <br />