Laserfiche WebLink
SAN J 0 A Q U I N Environmental Health Department <br /> " �� � ` ! ` COUNTY Linda Turkatte , REHS , Director <br /> \I Greatness y ro � y s here . Kasey Foley, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> June 13 , 2019 Muniappa Naidu , REHS <br /> Megan Mitchell <br /> Elite IV Contractors <br /> 2535 Wigwam Dr . <br /> Stockton , CA 95205 <br /> Re : Waterloo Shell SR0080525 <br /> 4315 E . Waterloo Rd . , Stockton , CA 95215 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to replace a short section of 87 product piping outside the 87 STP sump on the <br /> underground storage tank ( UST) system at the above noted address . The permit has been approved <br /> with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Stacy Rivera at (209 ) 468 - 3440 to arrange the following inspection appointments ( a <br /> 48 - hour notice is required for inspection appointments) . Please be aware that inspections for <br /> emergency work must be scheduled within five days of permit approval . <br /> a . Primary piping soap test : One hour pneumatic pressure test at 110 % of operating pressure , <br /> or 40 psi , whichever is greater. <br /> b . Secondary piping soap test : One hour pressure test per manufacturer' s guidelines . If there <br /> are no manufacturer' s guidelines , test shall be performed using an applicable method <br /> specified in an industry code or engineering standard . <br /> c . Primary piping test : Witness tightness test performed by SWRCB licensed tank tester or <br /> receive passing 0 . 1 gallon per hour test results from the PLLD ( if installed ) , after repouring <br /> of concrete . <br /> d . Verification of leak monitoring (vacuum ) communication for the 87 piping . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) , and <br /> c . Possesses a valid , current certificate of training from the manufacturer( s ) of the <br /> component (s) being tested , repaired , or serviced . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468- 3420 1 F 209 464-0138 1 www . sjcehd . com <br />