Laserfiche WebLink
San Joaquin County <br /> °V'NEnvironmental Health Department DIRECTOR <br /> Linda Turkatte,REHS <br /> 1868 E Hazelton Avenue <br /> Stockton, California 95205 PROGRAM COORDINATORS <br /> • Robert McClellon,REHS <br /> . � Jeff Carruesco,REHS, RDI <br /> Website: www.sjcehd.com Kasey Foley,REHS <br /> Adrienne Ellsaesser,REHS <br /> Phone: (209)468-3420 Rodney Estrada,REHS <br /> Fax: (209)464-0138 <br /> June 15, 2016 <br /> CARL WAYNE HENDERSON FILE CSERVICE STATION TESTING -SST INC <br /> PO BOX 31465 <br /> STOCKTON, CA 95213 <br /> Re: J & L MARKET SR0074938 <br /> 8115 S EL DORADO ST <br /> FRENCH CAMP, CA 95231 <br /> The San Joaquin County Environmental Health Department(EHD) has completed the review of the <br /> application for a permit to replace the 91/diesel annular sensor on the underground storage tank(UST) <br /> system at the above noted address. This work was completed on May 25, 2016. The permit has been <br /> approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Stacy Rivera at(209)468-3440 to arrange the following appointments (a 48-hour notice is <br /> required for inspection appointments). Please be aware that inspections for emergency work must be <br /> scheduled within five days of permit approval. <br /> • Sensor functionality: Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of Regulations <br /> and the Health & Safety Code. If it is determined that a cold start is necessary, a copy of the <br /> alarm history shall be printed prior to performing the"cold start" of the monitoring system and <br /> made available at the time of EHD inspection. <br /> 4. If concrete will be broken near the 91/diesel tank, a secondary containment test must be performed on <br /> the 91/diesel tank once concrete is poured in accordance with the manufacturer's guidelines. <br /> 5. Any individual performing the work of a service technician must meet the following qualifications: <br /> a. Possess or be employed by a person who possesses one of several permissible valid, current <br /> contractor's licenses issued by the Contractors State License Board (may be issued to the <br /> installation company), or a Tank Tester's license issued to the individual by the State Water <br /> Board, and <br /> b. Possess or work under the direct and personal supervision of an individual physically present at <br /> the work site who possesses a valid, current California UST Service Technician certificate issued <br /> by the International Code Council (ICC), and <br /> c. Possesses a valid, current certificate of training from the manufacturer(s) of the component(s) <br /> being tested, repaired, or serviced. <br />