Laserfiche WebLink
GREGG IN SITU, INC. ADVANCED GEO <br /> December 13, 2002 Hess DuBois <br /> 02-182ma Stockton, Ca. <br /> In situ groundwater samples were taken at three locations. Groundwater samples were <br /> collected using a Hydropunch® type groundwater sampling system (figure 2). The <br /> groundwater sampler operates by pushing 1.75 <br /> attached diameter <br /> hotipllo At rods with a <br /> desired <br /> retrievable tip. A stainless steel filter screen <br /> sampling depth, the rods are retracted exposing the filter screen and allowing for <br /> groundwater infiltration. A small diameter bailer is then used to collect groundwater <br /> samples through the.hollow rod. <br /> 3.0 CONE PENETRATION TEST DATA & INTERPRETATION <br /> The cone penetration test data is presented in graphical form. Penetration depths are <br /> referenced to existing ground surface. This data includes CPT logs of measured soil <br /> parameters and a computer tabulation of interpreted sail types along with additional <br /> geotechnical parameters and pore pressure dissipation data. <br /> The stratigraphic interpretation is based on relationships between cone bearing (qc), <br /> sleeve friction (fs), and penetration pore pressure (U). The friction ratio (RD, which is <br /> sleeve friction divided by cone bearing, is a calculated parameter which is used to infer <br /> soil behavior type. Generally, cohesive soils (clays) have high friction ratios, low cone <br /> bearing and generate large excess pore water pressures. Cohesionless soils (sands) <br /> have lower friction ratios, high cone bearing and generate little in the way of excess <br /> pore water pressures. <br /> Pore Pressure Dissipation Tests (PPDT's) were taken at various intervals in order to <br /> measure hydrostatic water pressures and approximate depth to groundwater table. In <br /> addition, the PPDT data can be used to estimate the horizontal permeability (kh) of the <br /> soil. The correlation to permeability is based on the time required for 50 percent of the <br /> measured dynamic pore pressure to dissipate (t5o). The PPDT correlation figure (fgure <br /> 3) is provided in the Appendix. <br /> The interpretation of soils encountered on this project was carried out using recent <br /> correlations developed by Robertson et al, 1990. It should be noted that it is not always <br /> possible to clearly identify a soil type based on qc, fs and U. In these situations, <br /> experience and judgement and an assessment of the pore pressure dissipation data <br /> should be used to infer the soil behavior type. The soil classification chart (figure 4) <br /> used to interpret soil types based on qc and Rf is provided in the Appendix. <br /> Interpreted output requires that depth of water be entered for calculation purposes, <br /> where depth to water is unknown an arbitrary depth in excess of 10 feet of the deepest <br /> sounding is entered as the groundwater depth. <br />