My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0002615
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
300
>
3500 - Local Oversight Program
>
PR0544424
>
ARCHIVED REPORTS XR0002615
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2019 11:57:05 AM
Creation date
5/6/2019 11:22:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002615
RECORD_ID
PR0544424
PE
3529
FACILITY_ID
FA0005099
FACILITY_NAME
HESS DUBOIS CLEANERS
STREET_NUMBER
300
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95203
CURRENT_STATUS
02
SITE_LOCATION
300 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GREGG IN SITU, INC. ADVANCED GEO <br /> December 13, 2002 Hess DuBois <br /> 02-182ma Stockton, Ca. <br /> In situ groundwater samples were taken at three locations. Groundwater samples were <br /> collected using a Hydropunch® type groundwater sampling system (figure 2). The <br /> groundwater sampler operates by pushing 1.75 <br /> attached diameter <br /> hotipllo At rods with a <br /> desired <br /> retrievable tip. A stainless steel filter screen <br /> sampling depth, the rods are retracted exposing the filter screen and allowing for <br /> groundwater infiltration. A small diameter bailer is then used to collect groundwater <br /> samples through the.hollow rod. <br /> 3.0 CONE PENETRATION TEST DATA & INTERPRETATION <br /> The cone penetration test data is presented in graphical form. Penetration depths are <br /> referenced to existing ground surface. This data includes CPT logs of measured soil <br /> parameters and a computer tabulation of interpreted sail types along with additional <br /> geotechnical parameters and pore pressure dissipation data. <br /> The stratigraphic interpretation is based on relationships between cone bearing (qc), <br /> sleeve friction (fs), and penetration pore pressure (U). The friction ratio (RD, which is <br /> sleeve friction divided by cone bearing, is a calculated parameter which is used to infer <br /> soil behavior type. Generally, cohesive soils (clays) have high friction ratios, low cone <br /> bearing and generate large excess pore water pressures. Cohesionless soils (sands) <br /> have lower friction ratios, high cone bearing and generate little in the way of excess <br /> pore water pressures. <br /> Pore Pressure Dissipation Tests (PPDT's) were taken at various intervals in order to <br /> measure hydrostatic water pressures and approximate depth to groundwater table. In <br /> addition, the PPDT data can be used to estimate the horizontal permeability (kh) of the <br /> soil. The correlation to permeability is based on the time required for 50 percent of the <br /> measured dynamic pore pressure to dissipate (t5o). The PPDT correlation figure (fgure <br /> 3) is provided in the Appendix. <br /> The interpretation of soils encountered on this project was carried out using recent <br /> correlations developed by Robertson et al, 1990. It should be noted that it is not always <br /> possible to clearly identify a soil type based on qc, fs and U. In these situations, <br /> experience and judgement and an assessment of the pore pressure dissipation data <br /> should be used to infer the soil behavior type. The soil classification chart (figure 4) <br /> used to interpret soil types based on qc and Rf is provided in the Appendix. <br /> Interpreted output requires that depth of water be entered for calculation purposes, <br /> where depth to water is unknown an arbitrary depth in excess of 10 feet of the deepest <br /> sounding is entered as the groundwater depth. <br />
The URL can be used to link to this page
Your browser does not support the video tag.