My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8925
>
2800 - Aboveground Petroleum Storage Program
>
PR0528878
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2019 10:15:32 AM
Creation date
5/6/2019 4:28:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528878
PE
2832
FACILITY_ID
FA0017954
FACILITY_NAME
RAMOS OIL CARD LOCK
STREET_NUMBER
8925
Direction
W
STREET_NAME
THORNTON
STREET_TYPE
RD
City
THORNTON
Zip
95686
APN
00120078
CURRENT_STATUS
01
SITE_LOCATION
8925 W THORNTON RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of aboveground petroleum storage act violations that <br /> have not been addressed for RAMOS OIL CARD LOCK as of May06, 2019. <br /> Open violations from May 10, 2017 inspection <br /> Violation #618 - Failed to conduct inspections or integrity tests or maintain records for 3 years. <br /> Copies of inspection and testing records were not found on site. Inspections and tests must be conducted in <br /> accordance with the written procedures developed in the Spill Prevention, Control, and Countermeasure (SPCC) <br /> Plan. Records of these inspections and tests must be signed by the appropriate supervisor or inspector and kept on <br /> site with the SPCC Plan for a period of three years. Immediately locate a copy of all inspection and testing records <br /> for the last three years, maintain them on site, and submit copies to the EHD. <br /> Violation #622 - Failure to conduct spill prevention briefing for oil-handling personnel. <br /> No records of discharge prevention briefings were available on site. Discharge prevention briefings for oil handling <br /> personnel must be scheduled and conducted at least once a year to assure adequate understanding of the SPCC <br /> Plan for that facility. Such briefings must highlight and describe known discharges or failures, malfunctioning <br /> components, and any recently developed precautionary measures. Immediately schedule and conduct a discharge <br /> prevention briefing, ensure that they are scheduled and conducted at least once a year. <br /> Violation#710 - Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br /> -The SPCC Plan stated that tank integrity testing will be done in accordance with STI SP001, but did not include the <br /> details of that testing for the site to follow. <br /> -No records were available to integrity testing. <br /> Each aboveground container shall be tested and inspected for integrity on a regular schedule and whenever repairs <br /> are made. The qualifications of personnel performing tests and inspections, frequency and type of testing and <br /> inspections that take into account container size, configuration, and design shall be determined in accordance with <br /> industry standards. Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br /> testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive <br /> testing. Comparison records and other records of inspections and tests must be maintained on site. Immediately <br /> update the SPCC Plan to include the integrity testing information and conduct the necessary testing and submit a <br /> copy of the test results to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> Violation #715 - Failed to regularly test liquid level sensing devices to ensure proper operation. <br /> Liquid level sensing devices have not been tested regularly. Procedures and frequency of testing for these devices <br /> were not addressed in the Spill Prevention, Control, and Countermeasure (SPCC) plan. Liquid level sensing <br /> devices must be installed in accordance with CFR 112.8 and shall be regularly tested to ensure proper operation. <br /> Immediately conduct all necessary testing of liquid level sensing devices, or provide equivalence as allowed by CFR <br /> 112.7(a)(2). <br /> Violation #724 - Failed to conduct integrity and leak testing on buried piping any time it is worked on. <br /> No piping integrity test results were available on site. Buried piping shall be tested for integrity and leaks at the time <br /> of installation, modification, construction, relocation, or replacement. Immediately perform integrity and leak testing <br /> of this piping and ensure that piping is tested when required, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.