A7.04523RESTROOM1078'-0"8'-6"CL5'-9"2'-9"CL17" - 18"5'-0" CLR.10722.510.310.210.11.111.1010.512.222.2A9.010TYP.4'-6"12.26.39.39.29.4TYP.A7.082'-10"6.46.1112.15.2OPEN TO BEYOND5.22'-10"3'-6"5.26.412.1OPEN TO BEYOND6.116.125.12TYP.TYP.5.2ASEE SCHED.HEIGHTSEE SCHED.WIDTHFLUSH PANELTRIMFINISHES GENERAL NOTES1. ALL GYP. BD. WALLS AND CEILINGS TO BE LEVEL 5 FINISH, U.O.N.2. ALL GYP. BD. WALLS AND CEILINGS TO BE PAINTED P-1, U.O.N.3. ALL RESTROOMS TO HAVE TILE PATTERN 1 AT WALLS, U.O.N. SEE TILE PATTERN ELEVATIONS, THIS SHEET.4. REFER TO ROOM FINISHES PLAN FOR FLOORING PATTERNS, WHERE OCCURS.5. ALL CASEWORK TO FOLLOW AWS GUIDELINES.6. ALL LAMINATE TO RUN HORIZONTALLY.7. ALL SOLID SURFACING TO HAVE SQUARE EDGING.8. ALL OPEN CASEWORK TO HAVE MATCHING LAMINATE AS EXTERIOR FACING.9. ALL INTERIOR CASEWORK MELAMINE TO BE WHITE.10. CONTRACTOR TO MEET OR EXCEED NAAWS 3.0 CUSTOM OR PREMIUM GRADE STANDARDS.DOOR GENERAL NOTES1. ALL INTERIOR AND EXTERIOR DOORS ARE EQUIPPED WITH SINGLE EFFORT, NON-GRASPING TYPE HARDWARE (I.E. LEVER) CENTER BETWEEN 34" AND 44" ABOVE THE FLOOR. CBC SECTIONS 11B-404.2.5, 11B-404.2.9, 11B-404.2.7.2. ALL EXIT DOORS SHALL BE OPERABLE FROM INSIDE WITHOUT SPECIAL KNOWLEDGE OR USE OF A KEY. SECTION 1008.1.83. PROTECT PREFINISHED SURFACES AND REPAIR ANY DAMAGE.4. DOORS, HARDWARE AND THRESHOLDS SHALL COMPLY WITH ACCESSIBILITY REQUIREMENTS.5. WHERE CLOSERS ARE INDICATED, THE OPENING FORCE IS TO BE SET AS FOLLOWS:A. EXTERIOR DOORS - 5 LBS.B. INTERIOR NON-RATED DOORS - 5 LBS.6. ALL INTERIOR AND EXTERIOR DOORS TO HAVE A 10" SMOOTH, UNINTERRUPTED BOTTOM SURFACE OR PROVIDE A 10" HIGH KICK PLATE. 2013 CBC SECTION 1133B.2.9. TEMPERED GLASS WILL OCCUR AT THE FOLLOWING LOCATIONS WHEN ALL APPLY:A. AREA OF GLAZING IS GREATER THAN 9 SQ. FT.B. THE BOTTOM EDGE IS LESS THAN 18" ABOVE THE FLOOR.C. THE TOP EDGE IS MORE THAN 36" ABOVE THE FLOOR.D. A WALKING SURFACE WITHIN 36" HORIZONTALLY OF THE GLAZING.10. PROVIDE SIGNAGE THAT COMPLIES WITH CBC SECTION 1008.1.8.3. A READILY VISIBLE SIGN POSTED ON THE EGRESS SIDE OF THE DOOR OR ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE SIGN SHALL BE IN LETTERS 1" HIGH ON A CONTRASTING BACKGROUND.11. EACH GRADE LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED WITH A TACTILE EXIT SIGN WITH THE WORD "EXIT".12. EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE".13. DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM.14. ALL KEYED DOORS SHALL BE APPROVED BY OWNER FOR KEYED SEQUENCE.CERAMIC TILESTAINED & SEALED CONC. FLOORGYP & PAINT"Schluter®-DILEX-AHKA" COVED ALUM. TRANSITION TRIM OR EQ. CERAMIC TILE TRIM CAPSEE ELEV.SEALANT - COLOR TO MATCH GROUTWALL PER PLAN