Laserfiche WebLink
LIGHT SWITCH, +48" TO TOP OF BOX <br />• D = DIMMER <br />• 3 = SWAY <br />• P = PILOT SWITCH <br />• os = LINE VOLTAGE OCCUPANCY SENSOR <br />• T = TIMMER <br />• VS = VACANCY SENSOR <br />WALL MOUNT OCCUPANCY SENSOR (LINE VOLTAGE) <br />EMERGENCY LIGHTING <br />EXIT SIGN WITH 90 MIN BATTERY BACKUP <br />WALL MOUNT EMERGENCY LIGHT WITH 90 MIN BATTERY BACK <br />EXTERIOR LANDING EMERGENCY LIGHT. CONNECT <br />TO INTERIOR EXIT SIGN FOR POWER. <br />FIXTURES WITH INTEGRAL EMERGENCY BALLAST <br />LIGHTING FIXTURES <br />LINEAR FIXTURE <br />• SQUARE = RECESSED <br />• CIRCLE =SURFACE <br />DOWNLIGHT, SQUARE = RECESSED <br />WALL MOUNT <br />CEILING EXHAUST FAN <br />POLE MOUNT AREA LIGHT <br />ELECTRICAL LEGEND <br />MOUNTING HEIGHTS <br />CONVIENCE OUTLETS, <br />PHONE & DATA OUTLETS, <br />+15" TO BOTTOM <br />OF BOX <br />SYSTEMS FURNITURE <br />CONNECTIONS +15" TO <br />BOTTOM OF BOXES <br />LIGHT SWITCHES <br />FIRE ALARM MANUAL <br />PULL STATION SHALL NOT <br />REQUIRE "TIGHT GRASPING, <br />PINCHING OR TWISTING OF <br />THE WRIST" <br />12" TYPICAL <br />THERMOSTAT <br />OR WALL PHONE <br />FINISHED FLOOR <br />48" TO TOP <br />OF BOX <br />FINISHED CEILING <br />AUDIBLE FIRE ALARM APPLIANCE <br />NOT LESS THEN 90" AFF OR AT <br />LEAST 6" BELOW CEILING <br />VISUAL APPLIANCE TO BE <br />NOT LESS THAN 80" AFF MIN, <br />AND NOT MORE THAN 96" AFF <br />TO BOTTOM <br />TITLE 24 LIGHTING CONTROLS <br />LIGHT SWITCH <br />COMPONENTS OF DIMMING ROOM CONTROLLER <br />• US = LOW VOLTAGE OCCUPANCY SENSOR (CAT 5 OR AS REQUIRED) <br />• DRC = DIMMING ROOM CONTROLLER <br />• PE = LOW VOLTAGE DIMMING PHOTOCELL (CAT 5 OR AS REQUIRED) <br />• D = LOW VOLTAGE DIMMER (CAT 5 OR AS REQUIRED) <br />• R = PLUG LOAD CONTROLLER <br />• ADR = AUTOMATIC DEMAND RESPOSNE (FOR BUILDINGS OVER 10,000 SF) <br />BASIC LIGHTING CONTROLS <br />NOTES: <br />1. FOR SUBMITTAL INCLUDE FACTORY CONTROL DRAWINGS. <br />2. CONDUCT A CONTROLS PRE-CONSTRUCTION MEETING WITH CONTROLS <br />STARTUP TEAM. PROVIDE AGENDA AND ATTENDEES AS A SUBMITTAL. INCLUDE <br />DEVICE I.D. TAGS, PROGRAMMING, CABLE ROUTING, PROGRAM AND TIME <br />SCHEDULES AND DATE OF PROGRAMMING AND TESTING. <br />3. CONTRACTOR TO HAVE SYSTEM FACTORY SUPPORT FOR START UP, <br />PROGRAMMING AND COMMISSIONING. VERIFY OPERATIONAL HOURS WITH OWNER <br />PRIOR TO COMMISSIONING. <br />DRAFTING NOTATIONS <br />KEY NOTE, SEE SCHEDULE <br />EQUIPMENT TAG, SEE SCHEDULE <br />REFERENCE TO A DETAIL VIEW "A" ON SHEET E-2 <br />NEW ELECTRICAL <br />EXISTING ELECTRICAL OR DEMOLISHED WHERE NOTED <br />EXISTING DEVICE, TO REMAIN IN OPERATION <br />REMOVE DEVICE, KEEP REMAINDER OF CIRCUIT IN OPERATION <br />REMOVE, RELOCATE AND RECONNECT DEVICE ON EXISTING CIRCUIT, EXTEND CIRCUIT <br />ELECTRICAL LEGEND <br />N## <br />N## <br />A <br />E-2 <br />FIXTURE NOTATIONS: <br />A,(b),C-12 FIXTURE TYPE "A", SWITCH "b", CIRCUIT C-12 <br /> <br />(e) (E) <br />(r) (R) <br />(RR) <br />TELEPHONE BACKBOARD, PROVIDE #8 GND TO SERVICE GROUND <br />COMMUNICATIONS OUTLET, PHONE & DATA <br />PHONE ONLY OUTLET, PREWIRED WITH CAT 5e CABLE <br />DATA ONLY OUTLET JACK, PREWIRED WITH CAT 6 CABLE <br />ELECTRICAL POWER <br />COMMUNICATIONS <br />ALL LINE VOLTAGE WIRING IN CONDUIT, SEE GENERAL NOTES <br /> TICKS = # OF #12 WIRE, SHORT = HOT, LONG = NEUTRAL, DOT = GROUND, <br /> UNLESS NOTED OTHERWISE <br />120V OUTLET, +18" TO BOTTOM OF BOX <br />• S = SIGN <br />• F = FLOOR <br />• GFI = GROUND FAULT INTERUPTER <br />COUNTER OUTLET <br />QUADRUPLEX OUTLET <br />HALF SWITCHED OUTLETS <br />OUTLETS ON EMERGENCY SYSTEMS <br />DUCT SMOKE DETECTOR <br />JUCTION BOX <br />MOTOR / DISCONNECT <br />PANELBOARD <br /> <br />TRANSFORMER / SWITCHBOARD AS NOTED <br />SD <br />XX <br />(e)200 <br />3 <br />PANEL <br />"K" <br />(e)GROUND <br />(e)MAIN SERVICE <br />(e)120/208V BUS <br />M <br />2"C-4#3/0+1#4 GND <br />DANGER <br />ARC FLASH AND SHOCK HAZARD <br />FOLLOW ALL REQUIREMENTS IN NFPA 70E <br />FOR SAFE WORK PRACTICES AND FOR <br />PERSONAL PROTECTIVE EQUIPMENT <br />ARC FLASH LABELLING REQUIREMENT: <br />PROVIDE THE FOLLOWING LABEL AS A MINIMUM <br />FOR COMPLIANCE WITH NFPA AND NEC ON <br />THIS PROJECT: