Laserfiche WebLink
Monitoring System Certification-Page 2 of 3 RECEN , <br /> Site Address: 3434 Manthey Road Date of Testing/Servicing: 12113/17 <br /> JAN 12 2018 <br /> D. Results of Testing/Servicing <br /> Software Version Installed. 327.04 ENVIBONMENTAL HEAL, <br /> Com tete the following checklist: DEPARTMENT <br /> ® Yes ❑ No* Is the audible alarm operational? <br /> ® Yes ❑ No* Is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> ® N/A operational? <br /> ® Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) I& Sump/Trench Sensors; ISI Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ® Yes ❑ No <br /> ® Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> ❑ N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fillpoint(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 90 % <br /> IN Yes* ❑ No Was any monitoring equipment replaced?If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product;❑ Water. If yes, describe causes in Section E,below. <br /> ® Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if a licable. <br /> ® Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Replaced TLS Battery for PM Purposes. <br /> 87-91 are Split Tanks &Share Annular. <br /> Replaced 91 Fill Sump Sensor(VR 794380-208) Due to being Stuck in Alarm -Retested and <br /> Passed <br /> Replaced Annular Sensor(VR 794390-460) Due to being Stuck in Alarm -Retested and Passed <br /> Tested E-Stops &Shear Valves, All Passed. <br />