Laserfiche WebLink
SWRCB,January 2002 Page `P of <br /> 7. UNDER-DISPENSER CONTAINMENT C2Q TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard X Professional Engineer <br /> ❑Other(,Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Caldwell Systems Equipment Resolution: .005/30 min <br /> UDC#9-10 UDC# UDC# UDC# <br /> UDC Manufacturer: Bravo <br /> UDC Material: Fiberglass <br /> UDC Depth: 31" <br /> Height from UDC Bottom to Top 9" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 3" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Dry <br /> testing: <br /> Portion of UDC Tested 2"above Highest Piping Penetration <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both x Yes ❑No 11 NA <br /> ❑Yes El No ❑NA El Yes ❑No INA ❑Yes ❑No ❑NA <br /> product and water)?" <br /> Turbine shutdown response time <br /> Is system programmed for fail- x Yes ❑No [INA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No [INA <br /> safe shutdown? <br /> Was fail-safe verified to be ❑Yes x No ❑NA ❑Yes ❑No ❑x NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> o erational?" <br /> Wait time between applying <br /> pressure/vacuum/water and 5 min 5 min 5 min 5 min <br /> starting test <br /> Test Start Time: <br /> Initial Reading(Rj): 00 .00" .00" .00" <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: 30 min 30 min 30 min 30 min <br /> Change in Reading(RF-Ri): <br /> Pass/Fail Threshold or Criteria: .005/30 min .005/30 min .005/30 min .005/30 min <br /> Test Result: ❑ Pass x Fail ❑ Pass ❑Fail ❑ Pass ❑ Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? x Yes ❑No ❑NA x Yes ❑No ❑NA x Yes ❑No ❑NA x Yes ❑No ❑NA <br /> Was sensor properly replaced and x Yes ❑No ❑NA x Yes ❑No ❑NA x Yes ❑No [INAx Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Boot will not seal on rock guard \ <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to aM of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />