My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:39:19 PM
Creation date
5/7/2019 10:21:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> -COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FOOD 4 LESS FUEL CENTER" 1 3408 MANTHEY RD, STOCKTON December 13, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For tank ID number TA 0515605 under"Tank <br /> Monitoring is Performed Using the Following Method(s)"the"Continuous Electronic Tank Monitoring"should be <br /> "Yes"and all appropriate information should be provided, under"Pipe Monitoring is Performed Using the Following <br /> Method(s)"the"ELLD Model' number should be PLLD and"Leak Sensor Model'should be 208. For both tanks <br /> under"Periodic System Testing", "ELD Testing should be"No". under"Under Dispenser Containment(UDC) <br /> Monitoring"change"Yes"to"No"in the"UDC Monitoring Stops Flow of Product at Dispenser and change the"Panel <br /> Model#"to the observed"350 PLUS'were applicable. The monitoring plan must be uploaded to the California <br /> Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit <br /> for review by the EHD. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 204 CCR 2712(i)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 91 fill sump sensor was found to be in alarm after being lifted for testing and did not come out of alarm. All <br /> monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The <br /> sensor was replaced and retested during the inspection. A"UST Retrofit Verification with Inspector Already Onsite" <br /> form has been completed and provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 307 CCR 2631(g), 2632(c)Monitoring system of the interstitial space of a double walled system not maintained. <br /> The 87/91 annular sensor failed come out of alarm after being tested, therefore,the tank is not monitored. The <br /> interstitial space shall be monitored with a monitoring system connected to an audible and visual alarm system. The <br /> sensor was replaced and retested during the inspection. A"UST Retrofit Verification with Inspector Already Onsite" <br /> form has been completed and provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> FA0013484 PR0517521 SCO01 12/13/2017 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.