Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10500
>
2800 - Aboveground Petroleum Storage Program
>
PR0516151
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 9:13:36 AM
Creation date
5/7/2019 10:35:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0516151
PE
2832
FACILITY_ID
FA0005245
FACILITY_NAME
Granite Construction Company-French Camp Facility
STREET_NUMBER
10500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
Rd
City
French Camp
Zip
95231
APN
193-270-03
CURRENT_STATUS
01
SITE_LOCATION
10500 S Harlan Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S b N J 0 A Q U I N Environmental Health Department <br /> COUNTY— <br /> Aboveground <br /> CUNTYAboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Granite Construction Company-French Camp 1 10500 S Harlan Rd, French Camp April 25, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 717 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas. <br /> The secondary containment for AST 14 was observed with liquid petroleum product underneath and on the south <br /> side of the tank. Visible discharges which result in a loss of oil from a container, including but not limited to seams, <br /> gaskets, piping, pumps, valves, rivets, and bolts, must be promptly corrected. Immediately clean up the cutback oil <br /> and manage according to the California Code of Regulations Title 22 hazardous waste regulations. <br /> This is a repeat violation, Class II. <br /> 718 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br /> containers. <br /> The 55 gallon drums located in the connex box storage area were observed with insufficient secondary containment. <br /> 55 gallon drums of petroleum product were observed inside of secondary containment pallets instead of sitting on a <br /> grate above the secondary containment pallet. Portable oil storage containers must be positioned or located to <br /> prevent a discharge and shall be furnished with a secondary means of containment sufficient to contain the capacity <br /> of the largest single container with sufficient freeboard to contain precipitation. Immediately provide sufficient <br /> secondary containment for this and all other portable containers at this facility, or provide equivalence as allowed by <br /> CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 726 CFR 112.8(c)(8)Plan failed to adequately describe overfill prevention methods for each container. <br /> Page 13 of the SPCC plan states"The diesel fuel tanks will be filled through pipes located <br /> within the east side of the secondary containment structure and are equipped with an audible overfill alarm." Per <br /> facility personnel no audible alarms are on the diesel fuel tanks and tank levels are determined by sticking the tank. <br /> Engineer or update each container installation in accordance with good engineering practice to avoid discharges.You <br /> must provide at least one of the following devices: (i)High liquid level alarms with an audible or visual signal at a <br /> constantly attended operation or surveillance station. In smaller facilities an audible air vent may suffice. (ii) High <br /> liquid level pump cutoff devices set to stop flow at a predetermined container content level. (iii)Direct audible or <br /> code signal communication between the container gauger and the pumping station. (iv)A fast response system for <br /> determining the liquid level of each bulk storage container such as digital computers,telepulse, or direct vision <br /> gauges. If you use this alternative, a person must be present to monitor gauges and the overall filling of bulk storage <br /> containers. (v)You must regularly test liquid level sensing devices to ensure proper operation.The SPCC plan should <br /> accurately describe overfill prevention. Provide a copy of the amended SPCC plan to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> FA0005245 PR0516151 SCO01 04/25/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 7 of 8 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.